20
4111-0012 — Sept. 2018
© 2018 Systems, LLC
1. Mount the push-button control panel (
B
) so
bottom of control panel-to-dock floor distance (
C
) is
48 in. (1219 mm). See Figure 14.
2. Install electrical disconnect panel (
A
) if not already
installed. Disconnect panel supplied by others.
3. Install and connect the control wiring (see
drawings supplied with equipment).
4. Connect the dock leveler power cable to the field
wires in the pit junction box.
5. Seal the conduit in any location where the conduit
crosses over temperature zones that could produce
condensation.
Optional:
Install spacers between the wall and
enclosure to provide temperature insulation and air
flow. If the conduit could fill with water, a drip leg
may be needed.
6. Install placard (see page 22).
Install Control Panel and Wiring
DO NOT connect the dock leveler electrical wiring
and ground connections until all welding has been
completed.
DO NOT ground welding equipment to any hydraulic
or electrical components of the dock leveler. Always
ground welding equipment to the dock leveler frame,
NEVER to the platform.
Failure to follow these instructions may damage the
motor, hydraulics, wiring, and/or control panel.
Make sure that the power source has been locked
out and tagged according to OSHA regulations and
approved local electrical codes.
All electrical work — including the installation of the
disconnect panel, control panel, and final connections
to the pit junction box — must be performed by a
certified electrician and conform to all local and
applicable national codes.
Where indicated, all components must be connected
to a SAFETY EARTH GROUND that conforms to
the 1999 National Electrical Code Section 250-50
section (a) or section (c) for a grounding electrode
system.
1.50"
3.00"
Decal Size: 1.5 x 3
File Name: 1751-0736 Rev A
Arc Flash and
Shock Hazard
PPE [Personal Protection
Equipment] Required
De-energize equipment before
working on or inside. Do not
open cover without appropriate
PPE. Refer to NFPA 70E for
PPE requirements. This panel
may contain more than one
power source.
Hazardous Voltage
Will Result in Death
or Serious Injury
1751-0736 Rev A
B
A
C
A— Disconnect Panel
B— Control Panel
(provided by others)
C— Distance, 48 in. (1219 mm)
Figure 14
INSTALLATION
Содержание LHP Series
Страница 13: ...11 4111 0012 Sept 2018 2018 Systems LLC This page intentionally left blank INSTALLATION ...
Страница 25: ...23 4111 0012 Sept 2018 2018 Systems LLC INSTALLATION This page intentionally left blank ...
Страница 31: ...29 4111 0012 Sept 2018 2018 Systems LLC MAINTENANCE This page intentionally left blank ...
Страница 42: ...40 4111 0012 Sept 2018 2018 Systems LLC PARTS B A D C Lip and Platform Parts ...
Страница 47: ...45 4111 0012 Sept 2018 2018 Systems LLC PARTS This page intentionally left blank ...
Страница 49: ...47 4111 0012 Sept 2018 2018 Systems LLC PARTS This page intentionally left blank ...
Страница 50: ...48 4111 0012 Sept 2018 2018 Systems LLC This page intentionally left blank MISCELLANEOUS ...