background image

 

 

Part 12

CASH DRAWER 

The PST7700 installed with power management kit option is able to 

control most of the common cash drawers available on the market. However, it 
is recommended that the Posiflex CR-3100 or CR-3200 or CR-4000 or CR-
4100 or CR-4210 be used since the terminal has been designed to compliment 
these cash drawers both mechanically and electrically. 

The PST7700 will directly control the cash drawer using the cash 

drawer port (CR) both to operate the opening mechanism and to monitor the 
drawer open status. Both functions may be accomplished under software 
control of the COM1 serial port. 

Use the cable supplied with the CR-3X00/4X00 cash drawer (Part No. 

CCBLA-180) for connection to the CR port in PST7700. This cable has a 6 
pole plug at one end and a 8 pole plug at the other. The 8 pole plug should be 
inserted into the connector marked: “signal cable from POS Printer” at the rear 
of the cash drawer. The 6 pole plug should be inserted in the connector marked 
“CR” found in the rear room of the terminal. 

The user may also use the optional 2-in-1 cash drawer control cable 

CCBLA-238 to control 2 cash drawers in 1 port. It has a 6 pole plug at one end 
and two 8 pole plugs at the other. The 6 pole plug should be inserted in the 
connector marked “CR” found in the rear room of the terminal. Each 8 pole 
plug should be inserted into the connector marked “signal cable from POS 
Printer” at the rear of one of the cash drawers. The cable lengths for the two 8 
pole plugs are different. Use the shorter one for the original cash drawer 
“CR1” and use the longer one for the extended cash drawer “CR2” that will be 
distinguished by the software command. 

AC POWER 

The power supply operating voltage 

must

 be checked and altered if 

necessary. This must be done 

WITHOUT

 any connection to the AC power. 

The operating voltage adjustment switch is located close to the power 

input connector in the rear room. 

The switch should indicate either 115 volts or 230 volts. When set at 

115 volts the acceptable power supply voltage range is 90 volts to 130 volts 
whilst at 230 volts the acceptable power supply voltage ranges from 190 volts 
to 260 volts. 

The power supply cable should first be connected to the power inlet 

(but 

NOT

 the wall socket). This cable should be secured to the latticed bottom 

of the rear room using a cable tie provided. The cable may exit either at the 
side or back of the rear compartment by using the relevant breakout section in 
the chassis plastic molding. 

Содержание PST - 7700

Страница 1: ...ng without limitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual co...

Страница 2: ...ole system till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you ...

Страница 3: ...ided the wiring spaghetti associated with more traditional PC solutions This Open Standard Architecture ensures that this terminal can use the PC application software and development tools that are now inexpensively available and abundant The terminal may be used as a self contained unit or by using the integrated network interface as one of several terminals in a network system controlled by a ba...

Страница 4: ...xists COM1 is capable of providing a 5 V DC supply COM2 COM3 and COM4 each are capable of providing independently a 5 V DC or a 12 V DC supply All these DC supplies are achieved through internal jumper setting and they are all defaulted to give no DC supply at delivery Parallel Port Each PST system is equipped with a parallel port that supports SPP EPP ECP USB Device Connection The PST7700 series ...

Страница 5: ...already purchased PST product h Integrated FDD 3 5 1 44 MB i Power management kit with CR port The most advanced UPS functions to safeguard the POS operation against intermittent power failure with another option UPS battery careless touch on the power switch unmanned remote account consolidation operation etc j 2 in 1 Cash Drawer Control Cable Cable CCBLA 238 when added to the optional CR port of...

Страница 6: ...e dependent accessories as listed below l Recovery CD for preloaded OS or Posiflex Product Information CD for driver utilities without OS l Cable tie 5 pieces l VFD terminator 1 piece l COM1 terminator 1 piece l Main power cord 1 piece The content of keyboard type dependent accessories is listed below Please note that these parts are different in size between the KB112 for PST7700 PST7705 and the ...

Страница 7: ...is ordered Connect the cable through the opening on the wall toward the rear room of the cabinet to the connector in the rear room Always disconnect the UPS battery when the system is to be left powered off for more than few days Please pay particular attention to the environment requirement for UPS battery in next chapter USING THE PST SYSTEM CRT MONITOR Upon receiving the CRT type PST7700 the mo...

Страница 8: ...unted To remove the monitor first disconnect the cable then pull the latch on the underside of the cable cover to remove the cable cover Then pull the monitor hook lever at rear bottom of the bowl by finger then raise and rotate the monitor forward till the CRT front is facing downward LCD CASHIER DISPLAY When the PST7705 or PST7735 is ordered the user has to take the 12 1 TFT LCD cashier display ...

Страница 9: ...ustomer display or VFD Please remove the VFD terminator from this connector and store in a safe place Insert the cable plug of the customer display into customer display connector until a click sound is heard Please NOTE The VFD connector must always be populated either with the VFD terminator or a plug from the customer display Failure to do this will prevent COM1 from working correctly Close the...

Страница 10: ...o so could result in permanent damage Please note that on at least one side of the square stem of the key top there is a small latching tab to match with a corresponding tab on the bottom inner side of the guide hole as in the example drawing above The system integrator can program the content of the keyboard for the application software following the technical guidance of Posiflex keyboard progra...

Страница 11: ...or internally connected KB wedge device is done We strongly advise users to consult with their dealers to have an authorized technician for such installation PRINTER Assemble the printer following the instructions supplied with the printer Remove the battery cover as in UPS battery section The user may find the UPS battery lying in the battery compartment if this option is ordered Connect the prin...

Страница 12: ...t has a 6 pole plug at one end and two 8 pole plugs at the other The 6 pole plug should be inserted in the connector marked CR found in the rear room of the terminal Each 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear of one of the cash drawers The cable lengths for the two 8 pole plugs are different Use the shorter one for the original cash draw...

Страница 13: ...efinitely observe the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months for temperature lower than 30 C Recharge for 1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided...

Страница 14: ...connector and is supported by the UPS function if the power management option is installed The video memory of this port shares the system memory The video memory size can be set in the CMOS setting to match the user s application Customer Display Port The customer display connector must always be occupied either by the terminator plug as supplied or by one of the family of Posiflex customer displ...

Страница 15: ...uch that the main power to the system may be controlled by many methods as below 1 Hardware power switch 2 Software OFF command 3 Automatic power ON control 4 Emergency power OFF Switching from OFF to ON requires a normal supply of the AC power Hardware Power Switch This button is located on the lower right hand front edge of the keyboard and can be used to turn the system on and off alternatively...

Страница 16: ...ed off It will take about 4 seconds if no power management kit installed and it takes about 10 seconds if the option installed If there appears to give a special coded beep tone in the pattern short long short long short prior to the system power off in this process please remove the AC power and wait for few minutes to allow the hardware registers to reset If there is no such beep AC removal is n...

Страница 17: ...on switch The horizontal rotation is almost 360 degrees for any required viewing direction The up down tilt of PD 2201 PD 2301 and PD 7201 provide 2 different view angles 14 5 and 30 However there are 8 viewing angles for PD 101 ranging from 2 5 to 60 PROGRAMMABLE KEYBOARD The standard programmable keyboard for PST7700 7705 is a 8 x 14 matrix layout keyboard coded as KB112 The keyboard for PST7730...

Страница 18: ...T7700 series in the front door area To enter the Hot Key programming mode press the left Alt key and the PRT SC Print Screen key on the PS 2 keyboard at the same time and press the key on the programmable keyboard to be updated after two beeps from the system Please then use the PS 2 keyboard to type the content to be programmed for that key Press both the left Alt key and the PRT SC Print Screen ...

Страница 19: ...l 1 44MB 3 5 Floppy Disk Drive FDD behind the door EXTERNAL PC KEYBOARD From time to time it will be necessary or more convenient to use a standard PC keyboard This may be to reprogram the PST keyboard key definitions or to alter some aspects of either the DOS operating system or the application program The PC keyboard may be plugged into the 5 pin DIN socket behind the front door This socket may ...

Страница 20: ...eloaded OS there is a function built in for system protection A screen as below will pop up for a short period of time in operation system booting up stage In normal practice nothing has to be done and the system boot up continues However this function is useful for our end users to fight against virus attacks or malicious system invasions nowadays or even some possible system crash Please connect...

Отзывы: