background image

 

 

Part 19

of the slot, or sliding the card upward from the lower side of the slot till it 
reaches the top end as long as the card is a standard one. A non-standard card 
recorded without complete degaussing prior to recovery may accept only one 
direction in card reading. 

The MSR indicator will light up in green when the MSR is ready to 

read, blink during reading, and then give a green light if the reading is 
successful. The MSR indicator will turn to be red if the reading fails due to 
improper sliding or poor magnetic intensity of the magnetic stripe, the MSR 
indicator will then turn back to green when the MSR is again ready to read. 

FRONT DOOR 

At the front of the programmable keyboard there is a door with a 

mechanical lock to the right of it. Turning the key clockwise will release the 
front door lock, the door may be fully opened  by hand then. This lock also 
physically locks the programmable keyboard subassembly housing to the 
chassis of the main unit, which prevents unauthorized access to the internal 
electronics. There are the external PC keyboard connector and the optional 
1.44MB 3.5” Floppy Disk Drive (FDD) behind the door. 

EXTERNAL PC KEYBOARD 

From time to time it will be necessary or more convenient to use a 

standard PC keyboard. This may be to reprogram the PST keyboard key 
definitions, or to alter some aspects of either the DOS operating system or the 
application program. The PC keyboard may be plugged into the 5 pin DIN 
socket behind the front door. 

This socket may also be used to trial a new device that is required to 

be daisy chained to the keyboard port (e.g. a table scanner). Please keep in 
mind the previously mentioned limit of 5 devices. 

3.5” FDD 

This option is a regular PC device, it accepts any 3.5” floppy diskette 

formatted to 1.44 MB or 720 KB. 

REAR ROOM 

The terminal has a rear room that covers the signal and power 

connector area and is designed to provide a tidy and secure termination for all 
cables into and out of the terminal. Cables may be secured by attaching them 
with cable ties to the lattice base of the compartment. 

Access to the rear room is gained by releas ing the rear door latches. 

These are located under the lower edge of the door at either side of the door. 
They may be located by “feeling the ridges” on the latch, sliding both latches 
to the center of the door will release the door. These latches are intentionally 
stiff. 

Содержание PST - 7700

Страница 1: ...ng without limitation loss of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual co...

Страница 2: ...ole system till completely exhausted Repeatedly using it up or improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you ...

Страница 3: ...ided the wiring spaghetti associated with more traditional PC solutions This Open Standard Architecture ensures that this terminal can use the PC application software and development tools that are now inexpensively available and abundant The terminal may be used as a self contained unit or by using the integrated network interface as one of several terminals in a network system controlled by a ba...

Страница 4: ...xists COM1 is capable of providing a 5 V DC supply COM2 COM3 and COM4 each are capable of providing independently a 5 V DC or a 12 V DC supply All these DC supplies are achieved through internal jumper setting and they are all defaulted to give no DC supply at delivery Parallel Port Each PST system is equipped with a parallel port that supports SPP EPP ECP USB Device Connection The PST7700 series ...

Страница 5: ...already purchased PST product h Integrated FDD 3 5 1 44 MB i Power management kit with CR port The most advanced UPS functions to safeguard the POS operation against intermittent power failure with another option UPS battery careless touch on the power switch unmanned remote account consolidation operation etc j 2 in 1 Cash Drawer Control Cable Cable CCBLA 238 when added to the optional CR port of...

Страница 6: ...e dependent accessories as listed below l Recovery CD for preloaded OS or Posiflex Product Information CD for driver utilities without OS l Cable tie 5 pieces l VFD terminator 1 piece l COM1 terminator 1 piece l Main power cord 1 piece The content of keyboard type dependent accessories is listed below Please note that these parts are different in size between the KB112 for PST7700 PST7705 and the ...

Страница 7: ...is ordered Connect the cable through the opening on the wall toward the rear room of the cabinet to the connector in the rear room Always disconnect the UPS battery when the system is to be left powered off for more than few days Please pay particular attention to the environment requirement for UPS battery in next chapter USING THE PST SYSTEM CRT MONITOR Upon receiving the CRT type PST7700 the mo...

Страница 8: ...unted To remove the monitor first disconnect the cable then pull the latch on the underside of the cable cover to remove the cable cover Then pull the monitor hook lever at rear bottom of the bowl by finger then raise and rotate the monitor forward till the CRT front is facing downward LCD CASHIER DISPLAY When the PST7705 or PST7735 is ordered the user has to take the 12 1 TFT LCD cashier display ...

Страница 9: ...ustomer display or VFD Please remove the VFD terminator from this connector and store in a safe place Insert the cable plug of the customer display into customer display connector until a click sound is heard Please NOTE The VFD connector must always be populated either with the VFD terminator or a plug from the customer display Failure to do this will prevent COM1 from working correctly Close the...

Страница 10: ...o so could result in permanent damage Please note that on at least one side of the square stem of the key top there is a small latching tab to match with a corresponding tab on the bottom inner side of the guide hole as in the example drawing above The system integrator can program the content of the keyboard for the application software following the technical guidance of Posiflex keyboard progra...

Страница 11: ...or internally connected KB wedge device is done We strongly advise users to consult with their dealers to have an authorized technician for such installation PRINTER Assemble the printer following the instructions supplied with the printer Remove the battery cover as in UPS battery section The user may find the UPS battery lying in the battery compartment if this option is ordered Connect the prin...

Страница 12: ...t has a 6 pole plug at one end and two 8 pole plugs at the other The 6 pole plug should be inserted in the connector marked CR found in the rear room of the terminal Each 8 pole plug should be inserted into the connector marked signal cable from POS Printer at the rear of one of the cash drawers The cable lengths for the two 8 pole plugs are different Use the shorter one for the original cash draw...

Страница 13: ...efinitely observe the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months for temperature lower than 30 C Recharge for 1 2 hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided...

Страница 14: ...connector and is supported by the UPS function if the power management option is installed The video memory of this port shares the system memory The video memory size can be set in the CMOS setting to match the user s application Customer Display Port The customer display connector must always be occupied either by the terminator plug as supplied or by one of the family of Posiflex customer displ...

Страница 15: ...uch that the main power to the system may be controlled by many methods as below 1 Hardware power switch 2 Software OFF command 3 Automatic power ON control 4 Emergency power OFF Switching from OFF to ON requires a normal supply of the AC power Hardware Power Switch This button is located on the lower right hand front edge of the keyboard and can be used to turn the system on and off alternatively...

Страница 16: ...ed off It will take about 4 seconds if no power management kit installed and it takes about 10 seconds if the option installed If there appears to give a special coded beep tone in the pattern short long short long short prior to the system power off in this process please remove the AC power and wait for few minutes to allow the hardware registers to reset If there is no such beep AC removal is n...

Страница 17: ...on switch The horizontal rotation is almost 360 degrees for any required viewing direction The up down tilt of PD 2201 PD 2301 and PD 7201 provide 2 different view angles 14 5 and 30 However there are 8 viewing angles for PD 101 ranging from 2 5 to 60 PROGRAMMABLE KEYBOARD The standard programmable keyboard for PST7700 7705 is a 8 x 14 matrix layout keyboard coded as KB112 The keyboard for PST7730...

Страница 18: ...T7700 series in the front door area To enter the Hot Key programming mode press the left Alt key and the PRT SC Print Screen key on the PS 2 keyboard at the same time and press the key on the programmable keyboard to be updated after two beeps from the system Please then use the PS 2 keyboard to type the content to be programmed for that key Press both the left Alt key and the PRT SC Print Screen ...

Страница 19: ...l 1 44MB 3 5 Floppy Disk Drive FDD behind the door EXTERNAL PC KEYBOARD From time to time it will be necessary or more convenient to use a standard PC keyboard This may be to reprogram the PST keyboard key definitions or to alter some aspects of either the DOS operating system or the application program The PC keyboard may be plugged into the 5 pin DIN socket behind the front door This socket may ...

Страница 20: ...eloaded OS there is a function built in for system protection A screen as below will pop up for a short period of time in operation system booting up stage In normal practice nothing has to be done and the system boot up continues However this function is useful for our end users to fight against virus attacks or malicious system invasions nowadays or even some possible system crash Please connect...

Отзывы: