3.5.4.1.
Filling the cooling system with engine at normal operating temperature:
A special filling system to fill the engine water system when the engine is
at normal operating temperature is also available from Sobek. This
appliance consists of a fluid reservoir with a coupling. The reservoir is
charged with a pressure of 2.5 – 3.0 bars.
The system filling procedure should be carried out as follows:
•
Disconnect the quick release fitting in the engine bay and connect
the filling system coupling to the corresponding end of the quick-
release fitting.
•
The system is filled via the expansion tank.
3.5.4.2.
Heating of the filled cooling system
For the heating of an already filled system Sobek offer an extern heating
unit.