5
12-Pin Accessories Harness
Wire Wire
colour
Function
Description
1 BLUE
(-) ZONE 3
or AUX 3
500-mA negative output. This output can be used to control Trunk release
(1-sec. pulse) or can be set to operate as a Constant as long as the TRUNK
button is held pressed. (For sunroof or window closure.)
2 BROWN (-)
LOCK
Programmable 500-mA 1/10-sec, 7/10-sec or 4-sec negative output.
3 GREEN (-)
UNLOCK
Programmable 500-mA 1/10-sec, 7/10 -ec, 4-sec or DBL pulse negative
output.
4
WHITE /
BROWN
(-) ARM
Max 500-mA ground signal when the Doors are locked by remote control.
This wire will go to ground 1/4 sec. before the LOCK pulse, and go OFF
1/8 sec after LOCK. Must be connected to the OEM Arm wire (usually the
Dome Light).
NOTE:
The system will also give a re-arm pulse on this wire
after a remote-start shutdown.
5
WHITE /
GREEN
(-) DISARM
Max 500-mA, 1-sec. ground pulse when the Doors are unlocked by remote
control. Connect to the OEM Disarm wire of the vehicle.
NOTE:
The
system will also give a disarm pulse on this wire before a remote start.
6
BLUE /
WHITE
(+) POSITIVE
DOOR INPUT
This input should be used in vehicles which use a POSITIVE switching
Dome Light circuit. Connect to the Dome Light wire that tests +12 volts
with a Door open, and 0 volt with the Doors closed.
7
WHITE /
ORANGE
(-) STARTER
KILL (ARMED
OUTPUT)
This wire will provide a constant output (500 mA) when the system is
ARMED (locked by remote). Can be connected to an external starter
interrupt relay.
8 ORANGE
(-) PARKING
BRAKE INPUT
Connect to the NEGATIVE Parking Brake Indicator Light wire of the
vehicle. This wire can be found at the Parking Brake Lever itself.
NOTE:
The Parking Brake wire should test ground while the Brake is engaged.
9 VIOLET
(-) EXTERNAL
TRIGGER
INPUT
This input will start the vehicle when it receives a 1-second ground pulse
from an external pager system or timer Module. It will also shut down upon
a 1-sec. pulse when running by remote.
10 WHITE
(-) GROUND-
OUTPUT
500 mA constant ground output when running.
Will become active before remote Ignition ON, and shut off after the
system shuts down.
11 GRAY
(-) NEGATIVE
DOOR INPUT
This input should be used in vehicles using a NEGATIVE switching Dome
Light circuit. Connect to the Dome Light wire that tests 0 volt with a Door
open and +4volts or above with the Doors closed.
12 YELLOW
(+) GLOW-PLUG
INPUT
This positive input will monitor the Glow Plug Light in DIESEL mode, and
will wait until the Glow Plug Light goes out to crank the vehicle. Connect
to the “
positive when ON”
side of the Glow Plug Light in the vehicle.
NOTE:
The Glow Plug timing delay is 15 seconds if the Glow Plug is still
on before cranking. (25 seconds if run time is set to 30 min.)
2-Pin Harness
Wire Wire
colour
Function
Description
1
BLUE /
WHITE
(-) AUX 2
Negative 500mA output. Can be programmed for any one of the following
three options:
(1) Constant while LOCK+UNLOCK are p 1 sec after release of
buttons.
(2) LOCK + UNLOCK toggles ON / OFF. (Max.30 sec.)
(3) LOCK + UNLOCK toggles ON / OFF. (Max.60 sec.)
NOTE:
AUX 2 can be programmed for Priority Door Access.
2 YELLOW
(-) PARKING
LIGHTS
Negative 500 mA Parking Lights output.