background image

0507060400/010920/M DraftMax Basic | DraftMax Ultra 

14

6.2.1  Filter cartridges

The spare filter cartridges are supplied in a plastic bag and 

come with face mask and a pair of disposable gloves. It is 

recommended to replace both filter cartridges at the same 

time.

To replace the filter cartridges, do the following. 

Fig. 6.1

•  De-energize the unit.
• 

Unpack the replacement filters and keep the plastic bags.

•  Open the right door with the square key. Turn the square 

key to the 

left

 to unlock the door.

WARNING

Wait

 at least 60 seconds before open the door to 

allow the dust in the filter compartment to settle.

• 

Remove the used filter cartridges and pack them in the 

plastic bags in which the new filters are supplied.

• 

Seal the bags firmly with the supplied tie-wrap.

•  Clean the pre spark arresters and put them back. 
•  Empty the dust drawers below the pre spark arresters and 

the filter cartridges, preferably with an industrial vacuum 

cleaner. Put dust drawers back in place.

•  Remove the main spark arresters and clean them. 
• 

Clean the entire filter compartment, including the space 

left and right of the main spark arresters.

•  Put the main spark arresters back.
• 

Install new filter cartridges.

•  Close the door.
• 

Dispose of the used filter cartridges in accordance with 

state or local regulations.

Fig. 6.1  Filter replacement

If you have installed the optional HEPA kit, you must replace 

the HEPA filter as well.

6.2.2 

HEPA filter (option)

The HEPA filter is supplied in a plastic bag and comes with face 

mask and a pair of disposable gloves. You must replace the 

HEPA filter together with the filter cartridges.

To replace the HEPA filter, do the following. 

•  Open the door of the HEPA box.
• 

Unlock the HEPA filter (refer to Fig. 4.12B).

• 

Remove the used HEPA filter and pack it in the plastic bag 

in which the new filter is supplied.

• 

Clean the filter housing.

• 

Install a new HEPA filter. 

• 

Pull the two straps tightly to lock the filter. A click sound 

confirms that the filter is correctly locked.

•  Close the door.
• 

Dispose of the used HEPA filter in accordance with state or 

local regulations.

TROUBLESHOOTING

If the unit does not function (correctly), consult the 

checklist below to see if you can remedy the error 

yourself. Should this not be possible, contact your 

supplier.

Text printed in 

italics

 refers to options and 

accessories.

WARNING

Obey the safety regulations that are written in 

chapter 3 when you carry out the activities below.

After you have switched off the fan, wait at least 60 

seconds before you open any door.

Symptom

Problem

Possible 

cause

Solution

General

The fan does 

not start

The 

downdraft 

table does 

not function

No power 

supply

Connect the mains 

voltage

Main switch is 

off

Turn on the main 

switch

Motor defective Repair or replace 

the motor

ON/OFF button 

defective

Replace the ON/

OFF button

Fuse(s) 

defective

Check fuses F1, F2 

and F3 and replace 

if necessary

Thermal relay 

tripped

Check current 

settings and reset 

the thermal relay

Thermal relay 

defective

Replace the thermal 

relay

Left and/or 

right door open

Close and lock both 

doors

Safety switch in 

left and/or right 

door defective

Replace safety 

switch(es)

Содержание DRAFTMAX BASIC

Страница 1: ...www plymovent com Downdraft table DRAFTMAX BASIC ULTRA Installation and user manual EN...

Страница 2: ...y serve as a guideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of t...

Страница 3: ...1 2 General description The downdraft table is a workbench with an integrated extraction fan and filtration system that is used for welding grinding and plasma cutting applications Depending on the sp...

Страница 4: ...wer consumption 2 2 kW 3 HP Mains cord 3 m 10 ft 1 m 3 ft internal 2 m 6 ft external without plug Protection class IP 55 control box only Sound level according to ISO 3746 without options with silence...

Страница 5: ...welding and plasma cutting applications and recommended for grinding applications By the use of a backdraft kit the downdraft extraction capacity is reduced to approx 20 The remaining 80 is extracted...

Страница 6: ...d not to play with the product Intended use2 The product has been designed as a workbench with integrated extraction and filtration facility for welding and grinding purposes provided the appropriate...

Страница 7: ...xtinguishers suitable for fire classes ABC Service maintenance and repairs Obey the maintenance intervals given in this manual Overdue maintenance can lead to high costs for repair and revisions and c...

Страница 8: ...e panel Right side panel To install the side panels do the following Fig 4 7 Loosen the bolts on the loose side of the hinges and remove the washers Keep the bolts and washers Put the pins through the...

Страница 9: ...owndraft table Keep the 4 bolts Apply the draught strip A to the downdraft table Fig 4 11 A Draught strip Fig 4 12 Push a screwdriver or other tool at the position of the strips B to unlock the HEPA f...

Страница 10: ...e Silencer Outlet duct do the following Fig 4 14 If applicable remove the outlet panel of the downdraft table or the outlet panel of the HEPA box Keep the 4 bolts Apply the draught strip to the downdr...

Страница 11: ...l the movement sensor on top of the back panel or backdraft panel with the 2 bolts A Fig 4 20 A x2 Mounting of the movement sensor Fig 4 21 Lead the cable down the back side of the downdraft table Att...

Страница 12: ...e system will be opened thus decreasing the pressure until the system pressure has reached an appropriate level ATTENTION The compressed air must be dry and oil free according to ISO 8573 3 class 6 Co...

Страница 13: ...welding grinding Push the OFF button D after you have finished welding grinding to stop the fan 5 1 3 Filter replacement Fig 5 1 During use you must regularly check the pressure gauge B When the pres...

Страница 14: ...ution and carry out the maintenance at regular intervals any problems occurring will be detected and corrected before they lead to a total breakdown WARNING Overdue maintenance can cause fire The indi...

Страница 15: ...astic bag and comes with face mask and a pair of disposable gloves You must replace the HEPA filter together with the filter cartridges To replace the HEPA filter do the following Open the door of the...

Страница 16: ...leaned One of the membrane valves defective Replace both membrane valves Poor extraction capacity No filter cleaning Membrane valve s defective Replace both membrane valves Button MANUAL CLEANING does...

Страница 17: ...our own responsibility that the product DraftMax Basic DraftMax Ultra which this declaration refers to is in accordance with the conditions of the following Directives Machine Directive 2006 42 EC EM...

Страница 18: ...ion option option no Wheel set option option option option Dust tray lid recommended recommended option option DraftMax Ultra yes yes yes yes Back panel no no option option Backdraft kit required requ...

Страница 19: ...240 0000101408 0040900020 0040000040 0000102289 0328400130 0040900220 0000101348 0040900080 0040900090 0040900050 0040900060 0040900270 2x 0040000020 0040100060 0046030010 0040000030 0000110543 004090...

Страница 20: ...HP 208 240 480V 3ph 60Hz USA 0040900090 Motor downdraft table 3 kW 4 HP 600V 3ph 60Hz Canada 0040900120 Push button black 0040900130 Push button green incl LED 0040900180 Main switch 25A 0040900220 T...

Страница 21: ...www plymovent com 0507060400 010920 M DraftMax Basic DraftMax Ultra...

Отзывы: