0507060400/010920/M DraftMax Basic | DraftMax Ultra 

2

PREFACE

Using this manual

This manual is intended to be used as a work of reference for 

professional, well trained and authorised users to be able to 

safely install, use, maintain and repair the product mentioned 

on the cover of this document.

Pictograms and symbols

The following pictograms and symbols are used in this manual:

TIP

Suggestions and recommendations to simplify 

carrying out tasks and actions.

ATTENTION

A remark with additional information for the user. A 

remark brings possible problems to the user’s 

attention.

CAUTION!

Procedures, if not carried out with the necessary 

caution, could damage the product, the workshop or 

the environment. 

WARNING!

Procedures which, if not carried out with the 

necessary caution, may damage the product or 

cause serious personal injury. 

CAUTION!

Denotes risk of electric shock. 

WARNING!

Fire hazard! Important warning to prevent fire. 

WARNING!

Explosion hazard! Important warning to prevent 

explosions. 

Personal protective equipment (PPE)

Instruction to use respiratory protection when you 

do service, maintenance and repair jobs, as well as 

during functional testing. We recommend to use a 

half-face respirator according to EN 149:2001 + 

A1:2009, class FFP3 (Directive 89/686/EEC).

Personal protective equipment (PPE)

Instruction to use protective gloves when you do 

service, maintenance and repair jobs.

Text indicators

Listings indicated by “-” (hyphen) concern enumerations. 

Listings indicated by “•” (bullet point) describe steps to 

perform. 

Service and technical support

For information about specific adjustments, maintenance or 

repair jobs which are not dealt with in this manual, please 

contact the supplier of the product. He will always be willing to 

help you. Make sure you have the following specifications at 

hand:

 

- product name

 

- serial number

You can find these data on the identification plate.

INTRODUCTION

1.1 

Identification of the product

The identification plate contains, among other 

things, the following data:

 

- product name

 

- serial number

 

- supply voltage and frequency

 

- power consumption

1.2 

General description

The downdraft table is a workbench with an integrated 

extraction fan and filtration system that is used for welding, 

grinding, and plasma cutting applications. Depending on the 

specific application, the use of certain accessories is required 

and/or recommended (refer to paragraph 1.3).

Refer to the table in Fig. I on page 17 for more 

instructions per application.

The downdraft table features a work grid, a three-stage 

pre-filtration system for optimum spark arresting and two oval 

filter cartridges

1

. Both pre and main filters have dust drawers 

underneath. The working height of the downdraft table is 

adjustable.

1.2.1  DraftMax Basic

The filter cartridges of the DraftMax Basic are disposable.

1.2.2  DraftMax Ultra

The filter cartridges in the DraftMax Ultra are self-cleaning by 

means of an automatically controlled compressed air system.

1.3 

Options and accessories

The following products can be obtained as an option and/or 

accessory:

Refer to paragraph 2.3 for the functioning of the 

various options and accessories.

A  Back panel

The back panel consists of a sheet metal plate to be 

mounted on the downdraft table.

Backdraft kit 

(required for all welding and plasma 

cutting applications and recommended for grinding 

applications)

The backdraft kit consists of narrowing plates to be mounted 

below the workgrid and a backdraft panel with vertical 

lamellas. 

C  Side panels

The side panels consist of hinged trapezium-shaped sheet 

metal plates and have to be used in combination with the 

backdraft kit or back panel. They are to be mounted on the 

sides of the downdraft table. 

D  Plasma cutting work grid 

(required for plasma cutting 

applications)

Specially constructed work grid suitable for plasma cutting, 

including additional perforated steel spark arresters. 

E  HEPA kit

 (required for stainless steel welding)

Consists of a filter housing with a HEPA filter to be mounted 

on the outlet of the downdraft table. Filter surface area 34 

m² 

(366 ft²)

. Filter class: HEPA 11.

F  Silencer/Outlet duct

Consists of a rectangular sheet metal shaft to be mounted on 

the outlet of the downdraft table or on the HEPA kit. 

G  Outlet connection plate

For duct connetion of the downdraft table. It replaces the 

outlet panel. 

1.

  The filter cartridges are the main filters

Содержание DRAFTMAX BASIC

Страница 1: ...www plymovent com Downdraft table DRAFTMAX BASIC ULTRA Installation and user manual EN...

Страница 2: ...y serve as a guideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of t...

Страница 3: ...1 2 General description The downdraft table is a workbench with an integrated extraction fan and filtration system that is used for welding grinding and plasma cutting applications Depending on the sp...

Страница 4: ...wer consumption 2 2 kW 3 HP Mains cord 3 m 10 ft 1 m 3 ft internal 2 m 6 ft external without plug Protection class IP 55 control box only Sound level according to ISO 3746 without options with silence...

Страница 5: ...welding and plasma cutting applications and recommended for grinding applications By the use of a backdraft kit the downdraft extraction capacity is reduced to approx 20 The remaining 80 is extracted...

Страница 6: ...d not to play with the product Intended use2 The product has been designed as a workbench with integrated extraction and filtration facility for welding and grinding purposes provided the appropriate...

Страница 7: ...xtinguishers suitable for fire classes ABC Service maintenance and repairs Obey the maintenance intervals given in this manual Overdue maintenance can lead to high costs for repair and revisions and c...

Страница 8: ...e panel Right side panel To install the side panels do the following Fig 4 7 Loosen the bolts on the loose side of the hinges and remove the washers Keep the bolts and washers Put the pins through the...

Страница 9: ...owndraft table Keep the 4 bolts Apply the draught strip A to the downdraft table Fig 4 11 A Draught strip Fig 4 12 Push a screwdriver or other tool at the position of the strips B to unlock the HEPA f...

Страница 10: ...e Silencer Outlet duct do the following Fig 4 14 If applicable remove the outlet panel of the downdraft table or the outlet panel of the HEPA box Keep the 4 bolts Apply the draught strip to the downdr...

Страница 11: ...l the movement sensor on top of the back panel or backdraft panel with the 2 bolts A Fig 4 20 A x2 Mounting of the movement sensor Fig 4 21 Lead the cable down the back side of the downdraft table Att...

Страница 12: ...e system will be opened thus decreasing the pressure until the system pressure has reached an appropriate level ATTENTION The compressed air must be dry and oil free according to ISO 8573 3 class 6 Co...

Страница 13: ...welding grinding Push the OFF button D after you have finished welding grinding to stop the fan 5 1 3 Filter replacement Fig 5 1 During use you must regularly check the pressure gauge B When the pres...

Страница 14: ...ution and carry out the maintenance at regular intervals any problems occurring will be detected and corrected before they lead to a total breakdown WARNING Overdue maintenance can cause fire The indi...

Страница 15: ...astic bag and comes with face mask and a pair of disposable gloves You must replace the HEPA filter together with the filter cartridges To replace the HEPA filter do the following Open the door of the...

Страница 16: ...leaned One of the membrane valves defective Replace both membrane valves Poor extraction capacity No filter cleaning Membrane valve s defective Replace both membrane valves Button MANUAL CLEANING does...

Страница 17: ...our own responsibility that the product DraftMax Basic DraftMax Ultra which this declaration refers to is in accordance with the conditions of the following Directives Machine Directive 2006 42 EC EM...

Страница 18: ...ion option option no Wheel set option option option option Dust tray lid recommended recommended option option DraftMax Ultra yes yes yes yes Back panel no no option option Backdraft kit required requ...

Страница 19: ...240 0000101408 0040900020 0040000040 0000102289 0328400130 0040900220 0000101348 0040900080 0040900090 0040900050 0040900060 0040900270 2x 0040000020 0040100060 0046030010 0040000030 0000110543 004090...

Страница 20: ...HP 208 240 480V 3ph 60Hz USA 0040900090 Motor downdraft table 3 kW 4 HP 600V 3ph 60Hz Canada 0040900120 Push button black 0040900130 Push button green incl LED 0040900180 Main switch 25A 0040900220 T...

Страница 21: ...www plymovent com 0507060400 010920 M DraftMax Basic DraftMax Ultra...