Troubleshooting
Optical Sensor Calibration
Sensors should be calibrated if the machine
noticeably increases in frequency of misfeeds.
Calibration sub-menus for Optical DSD Sensor,
Ultrasonic DSD Sensor may be selected from the
Tools Menu.
Procedure - Calibration of Optical DSD
:
•
Select
Optical DSD tray 3
to calibrate the upper
tray’s sensor;
•
Select
Optical DSD tray 4
to calibrate the lower
tray’s sensor;
•
The selected tray opens;
•
Select
Optical DSD tray A
to calibrate the LSM
optical sensor and open the LSM top cover;
•
•
Open the LCT door and fetch the DSD
Calibration Strip [A];
Place the Calibration Strip as shown in the
pictures below;
•
Press
[Run];
•
Calibration complete. If calibration fails, old
settings will be kept.
A
Optical DSD Calibration Strip