CIP Training
Plockmatic LCT3500 Large Capacity Tray
Setting Up a Job
Ultrasonic DSD Sensor [A]
The LCT is equipped with three (in the
vacuum trays and in the optional LSM)
independent double sheet detection
systems, both optical and ultrasonic.
The ultrasonic sensor is active by default.
Push the green check mark to confirm
the changes or the red cross to discard
them and to go back to the main menu.
NOTE: The Ultrasonic DSD Sensor
does not work on all 400 gsm types of
paper, as paper density can vary signifi-
cantly.
Optical DSD Sensor [B]
NOTE: This function is currently
deactivated an will be available in the
future. The LCT is equipped with three (in
the vacuum trays and in the optional LSM)
independent double sheet detection
systems, both optical and ultrasonic.
The optical sensor is deactivated by
default. This sensor should only be
activated when the tray is loaded with
one type of paper and with the same
print job.
A
B
DSD Sensors
If this sensor is activated with different types of paper with different print jobs, it
will give false readings. Push the green check mark to confirm the changes or the
red cross to discard them and to go back to the main menu.
NOTE:
The Optical DSD Sensor does not work on sheets thicker than 250 gsm.