11.
TROUBLESHOOTING
Warning!
Installation, repair and maintenance must be performed only by a trained engineer with the
appropriate permissions, service company or gas supplier.
There are many factors that may affect the malfunction of the gas insert. To exclude a possible fault in the
unit or the automatic gas control system, make sure that the fireplace is connected according to these
instructions.
Below table summarizes possible failures that may occur, possible causes and ways to solve them.
ERROR
CODE
FAULT
POSSIBLE CAUSE
REPAIR
SMELL OF GAS
IMMEDIATELY CLOSE THE GAS VALVE ON THE GAS CONNECTION. DO
NOT USE THE APPLIANCE UNTIL SPILLS ARE FULLY REMOVED
F00
Flame not detected in time and
the burner control doesn’t
report a failure.
F01, F07 or F08 appeared 3 times
Device blocked. Wait 30 minutes before trying
again.
No spark
Make sure that the distance between the
electrodes is 3-4 mm
No Gas
Make sure, there is a gas connection
F01
The lack of communication
between the receiver and the
automation controller
Communication cable does not make
any contact
Make sure that the contacts of the communication
cable ensure correct contact
Damage to the communication cable
Replace the communication cable
F02
Overheating of the receiver (60 °
c above room temperature)
Poor ventilation by the receiver
Improve ventilation at the receiver
The receiver is in contact with the hot
parts
Move the receiver so that it does not touch the
hot parts
F03
Internal NTC sensor( of the
receiver) is not working properly
Damaged receiver
Replace Receiver
F04
External NTC sensor is not
working properly
External NTC sensor or wiring are
damaged
Replace the NTC sensor or wiring
F05
Internal security error
Damaged receiver
Replace Receiver
F06
Lack of communication between
the transmitter and receiver
The transmitter is out of range of the
receiver
Make sure that the transmitter is located near the
receiver
Any obstacles between the transmitter
and the receiver may interfere with the
signal
Remove any obstacles between the transmitter
and receiver
Power transmission is too weak
Check the power transmission (see. Instruction
Manual Chapter 9)
F07
Flame not detected in time and
the burner control doesn’t
report a failure.
No spark
Make sure that the distance between the
electrodes is 3-4 mm
No Gas
Make sure, there is a gas connection
F08
No ionisation / The burner
control reports a failure and the
flame could not be detected in
time.
No spark
Make sure that the distance between the
electrodes is 3-4 mm
Replace the ignition electrodes
Check if the cables for the ignition electrode are
connected correctly
No Gas
Make sure, there is a gas connection