5.3.
Gas connection
Gas control system used in a series of MONROE meets the requirements for appliances burning gaseous fuel
contained in directives 2009/142/EC and standards EN 298, EN 55014-1, EN 60730-1, EN 60335.
First and foremost, make sure that the connecting device is designed to supply a gas suitable for the type
placed in the gas installation. All necessary information regarding the desired parameters of the gas are found
on the rating plate of the device. Before connecting the gas supply, it is necessary to blow them to remove
any remaining metal filings and other contaminants from inside. Automatic gas control system should be
protected from moisture and dust. These factors may cause irreparable damage to the individual components.
The pipe supplying gas to the fireplace should be equipped with a ball valve with a diameter of 1/2 inch. The
individual elements of the gas installation cannot be sealed using Teflon tape or PTFE tape.
The gas valve on the gas pipe must be installed in accordance with applicable national regulations. Gas
connection "
G
in" on the main control valve of the fireplace is located next to the controller of the gas valve
"
C
". Before connecting the gas, make sure that the gas pipes and connections have no dirt. Gas connection is
finished with internal thread 3/8 ".
Regarding gas connection, the following requirements shall apply:
• You must use the gas pipe with the correct dimensions, so there are no pressure loss.
• Ball gas valve should be installed in an easily accessible place and have the necessary CE mark.