Set “MEP5” = Port2, “MEP6” = Port1 and VLAN ID = 3001; click “Set” button to save the ERPS configuration for Switch 3.
To avoid loop, please don’t connect Switches 1, 2 & 3 together in the ring topology before configuring
the end of ERPS .
Follow the configuration or ERPS wizard to connect Switches 1, 2 and 3 together to establish ERPS application:
MEP2
←→
MEP3 = Switch1 / Port2
←→
Switch2 / Port2
MEP4
←→
MEP5 = Switch2 / Port1
←→
Switch3 / Port2
MEP1
←→
MEP6 = Switch1 / Port1
←→
Switch3 / Port1.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...