![Planet IGS-5225 Series Скачать руководство пользователя страница 409](http://html1.mh-extra.com/html/planet/igs-5225-series/igs-5225-series_user-manual_1563274409.webp)
User’s Manual of IGS-5225 series
409
Functional Configuration
Continuity Check:
Object
Description
•
Enable
Continuity Check based on transmitting/receiving CCM PDU can be
enabled/disabled. The CCM PDU is always transmitted as Multi-cast Class 1.
•
Priority
The priority to be inserted as PCP bits in TAG (if any). In case of enable of
Continuity Check and Loss Measurement both implemented on SW based CCM,
'Priority' has to be the same.
•
Frame rate
Selecting the frame rate of CCM PDU. This is the inverse of transmission period
as described in Y.1731. This value has the following uses:
* The transmission rate of the CCM PDU.
* Fault Cause cLOC is declared if no CCM PDU has been received within 3.5
periods - see 'cLOC'.
* Fault Cause cPeriod is declared if a CCM PDU has been received with different
period - see 'cPeriod'.
Selecting 300f/sec or 100f/sec will configure HW based CCM (if possible).
Selecting other frame rates will configure SW based CCM. In case of enable of
Continuity Check and Loss Measurement both implemented on SW based CCM,
'Frame Rate' has to be the same.
APS Protocol:
Object
Description
•
Enable
Automatic Protection Switching protocol information transportation based on
transmitting/receiving R-APS/L-APS PDU can be enabled/disabled. Must be
enabled to support ERPS/ELPS implementing APS. This is only valid with one
Peer MEP configured.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...