![Planet IGS-5225 Series Скачать руководство пользователя страница 275](http://html1.mh-extra.com/html/planet/igs-5225-series/igs-5225-series_user-manual_1563274275.webp)
User’s Manual of IGS-5225 series
275
■
IPv4Uni
PTP over IPv4 unicast
•
VID
VLAN Identifier used for tagging the VLAN packets.
•
PCP
Priority Code Point value used for PTP frames.
•
DSCP
DSCP value used when transmitting IPv4 encapsulated packets
Clock Time Properties Data Set
The clock time properties data set is defined in the IEEE 1588 Standard. The data set is both configurable and dynamic, i.e. the
parameters can be configured for a grandmaster. In a slave clock the parameters are overwritten by the grandmasters timing
properties. The parameters are not used in the current PTP implementation.
The valid values for the Time Source parameter are:
■
16 (0x10) ATOMIC_CLOCK
■
32 (0x20) GPS
■
48 (0x30) TERRESTRIAL_RADIO
■
64 (0x40) PTP
■
80 (0x50) NTP
■
96 (0x60) HAND_SET
■
144 (0x90) OTHER
■
160 (0xA0) INTERNAL_OSCILLATOR
Object
Description
•
UtcOffset
In systems whose epoch is UTC, it is the offset between TAI and UTC
•
Valid
When true, the value of currentUtcOffset is valid
•
leap59
When true, this field indicates that last minute of the current UTC day has only 59
seconds.
•
leap61
When true, this field indicates that last minute of the current UTC day has 61
seconds.
•
Time Trac
True if the timescale and the value of currentUtcOffset are traceable to a primary
reference.
•
Freq Trac
True if the frequency determining the timescale is traceable to a primary reference.
•
ptp Time Scale
True if the clock timescale of the grandmaster clock and false otherwise.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...