![Planet IGS-5225 Series Скачать руководство пользователя страница 401](http://html1.mh-extra.com/html/planet/igs-5225-series/igs-5225-series_user-manual_1563274401.webp)
User’s Manual of IGS-5225 series
401
to the PoE device. Please be noticed that the PD’s IP address must be set to the
same network segment with IGS-5225-4UP1T2S/8P4S/8P2S/8P2S2X PoE Switch.
•
Interval Time (10~300s)
This column allows user to set how long system should be issue a ping request to
PD for detecting PD is alive or dead. Interval time range is from 10 seconds to 300
seconds.
•
Retry Count (1~5)
This column allows user to set how many times system rerry ping to PD. For
example, if we set count 2, the meaning is that if system retry ping to the PD and the
PD doesn’t response continuously, the PoE port will be reset.
•
Action
Allows user to set which action will be apply if the PD witout any response.
IGS-5225-4UP1T2S/8P4S/8P2S/8P2S2X PoE Switch offers 3 actions as following.
PD Reboot:
It menas system will reset the PoE port that connected the PD.
Reboot & Alarm:
It means system will reset the PoE port and issue an alarm
message via Syslog, SMTP.
Alarm:
It means system will issue an alarm message via Syslog, SMTP.
•
Reboot Time (30~180s)
This column allows user to set the
PoE PD device rebooting time
, due to there are
so many kind of PoE PD device on the market and theyhave different rebooting
time. The PD Alive-check is not a defining standard, so the PoE PD device on the
market doesn’t report reboots done information to IGS-6325 PoE Switch, so user
has to make sure
how long the PD will be finished to boot
, and then set the time
value to this column.
System is going to check the PD again according to the reboot time. If ou can not
make sure precisely booting time, we suggest you to set it longer.
Buttons
: Click it to save changes.
: Click it to reset configuration which doesn’t to be saved yet.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...