User’s Manual of IGS-5225 series
150
The page includes the following fields:
Object
Description
•
Session
Select session id to configure.
•
Mode
To Enabled/Disabled the mirror or Remote Mirroring function
•
Type
Mirror
The switch is running on mirror mode.
The
Source
The switch is a source node for monitor flow.
The
RMirror destination
The switch is an end node for monitor flow.
The
•
VLAN ID
The VLAN ID points out where the monitor packet will copy to. The default VLAN ID is
200.
•
Reflector Port
The reflector port is a method to redirect the traffic to Remote Mirroring VLAN. Any device
connected to a port set as a reflector port loses connectivity until the Remote Mirroring is
disabled.
In the stacking mode, you need to select switch ID to select the correct device.
If you shut down a port, it cannot be a candidate for reflector port.
If you shut down the port which is a reflector port, the remote mirror function cannot work
•
Source VLAN(s)
Configuration
The switch can supports VLAN-based Mirroring. If you want to monitor some VLANs on
the switch, you can set the selected VLANs on this field.
•
Remote Mirroring
Port Configuration
The following table is used for port role selecting.
■
Port
: The logical port for the settings contained in the same row..
■
Source:
Select mirror mode.
Disabled
Neither frames transmitted nor frames received are mirrored.
Both
Frames received and frames transmitted are mirrored on the
Destination
port
.
Rx only
Frames received on this port are mirrored on the
Destination port
.
Frames transmitted are not mirrored.
Tx only
Frames transmitted on this port are mirrored on the
Destination port
.
Frames received are not mirrored
■
Destination
:
Select destination port.
This checkbox is designed for mirror or Remote Mirroring.
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...