IPv4
: The ACE will match all IPv4 frames.
■
IPv4/ICMP
: The ACE will match IPv4 frames with ICMP protocol.
■
IPv4/UDP
: The ACE will match IPv4 frames with UDP protocol.
■
IPv4/TCP
: The ACE will match IPv4 frames with TCP protocol.
■
IPv4/Other
: The ACE will match IPv4 frames, which are not
ICMP/UDP/TCP.
■
IPv6
: The ACE will match all IPv6 standard frames.
•
Action
Indicates the forwarding action of the ACE.
■
Permit
: Frames matching the ACE may be forwarded and learned.
■
Deny
: Frames matching the ACE are dropped.
•
Rate Limiter
Indicates the rate limiter number of the ACE. The allowed range is 1 to 16. When
Disabled is displayed, the rate limiter operation is disabled.
•
CPU
Forward packet that matched the specific ACE to CPU
•
Counter
The counter indicates the number of times the ACE was hit by a frame.
•
Conflict
Indicates the hardware status of the specific ACE. The specific ACE is not
applied to the hardware due to hardware limitations.
Buttons
Auto-refresh
: Check this box to refresh the page automatically. Automatic refresh occurs every 3 seconds.
: Click to refresh the page.
4.5.5.2 Access Control List Configuration
This page shows the Access Control List (ACL), which is made up of the ACEs defined on this switch. Each row describes the
ACE that is defined. The maximum number of ACEs is
512
on each switch.
Click on the lowest plus sign to add a new ACE to the list. The reserved ACEs used for internal protocol, cannot be edited or
deleted, the order sequence cannot be changed and the priority is highest. The Access Control List Configuration screen in
Figure 4-5-5-2
appears.
Figure 4-5-5-2:
Access Control List Configuration Page Screenshot
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...