User’s Manual of IGS-5225 series
362
The page includes the following fields:
Object
Description
•
Ingress Port
Select the ingress port for which this ACE applies.
■
Any
: The ACE applies to any port.
■
Port n
: The ACE applies to this port number, where n is the number of the
switch port.
•
Policy Filter
Specify the policy number filter for this ACE.
■
Any
: No policy filter is specified. (policy filter status is "don't-care".)
■
Specific
: If you want to filter a specific policy with this ACE, choose this
value. Two field for entering an policy value and bitmask appears.
•
Policy Value
When "Specific" is selected for the policy filter, you can enter a specific policy value.
The allowed range is
0
to
255
.
•
Policy Bitmask
When "Specific" is selected for the policy filter, you can enter a specific policy bitmask.
The allowed range is
0x0
to
0xff
.
•
Frame Type
Select the frame type for this ACE. These frame types are mutually exclusive.
■
Any
: Any frame can match this ACE.
■
Ethernet Type
: Only Ethernet Type frames can match this ACE. The IEEE
802.3 describes the value of Length/Type Field specifications to be greater
than or equal to 1536 decimal (equal to 0600 hexadecimal).
■
: Only ARP frames can match this ACE. Notice the ARP frames won't
match the ACE with Ethernet type.
■
IPv4
: Only IPv4 frames can match this ACE. Notice the IPv4 frames won't
match the ACE with Ethernet type.
■
IPv6
: Only IPv6 frames can match this ACE. Notice the IPv6 frames won't
match the ACE with Ethernet type.
•
Action
Specify the action to take with a frame that hits this ACE.
■
Permit
: The frame that hits this ACE is granted permission for the ACE
operation.
■
Deny
: The frame that hits this ACE is dropped.
•
Rate Limiter
Specify the rate limiter in number of base units.
The allowed range is 1 to 16.
Disabled indicates that the rate limiter operation is disabled.
•
Port Redirect
Frames that hit the ACE are redirected to the port number specified here.
The allowed range is the same as the switch port number range.
Disabled indicates that the port redirect operation is disabled.
•
Mirror
Specify the mirror operation of this port. Frames matching the ACE are mirrored to the
destination mirror port. The rate limiter will not affect frames on the mirror port. The
allowed values are:
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...