![Planet IGS-5225 Series Скачать руководство пользователя страница 273](http://html1.mh-extra.com/html/planet/igs-5225-series/igs-5225-series_user-manual_1563274273.webp)
User’s Manual of IGS-5225 series
273
Clock current Data Set
Object
Description
•
stpRm
Steps Removed : It is the number of PTP clocks traversed from the grandmaster
to the local slave clock.
•
Offset from master
Time difference between the
master clock
and the
local slave clock
, measured
in
ns
.
•
Mean Path Delay
The mean propagation time for the link between the
master
and the
local slave
Clock Parent Data Set
The clock parent data set is defined in the IEEE 1588 standard. The parent data set is dynamic.
Object
Description
•
Parent Port Identity
Clock identity for the parent clock, if the local clock is not a slave, the value is the
clocks own id.
•
Port
Port Id for the parent master port
•
P Stat
Parents Stats (always false).
•
Var
It is observed parent offset scaled log variance
•
Rate
Observed Parent Clock Phase Change Rate. i.e. the slave clocks rate offset
compared to the master. (unit = ns per s).
•
Grand Master ID
Clock identity for the grand master clock, if the local clock is not a slave, the
value is the clocks own id.
•
Grand Master Clock
Quality
The clock quality announced by the grand master (See description of Clock
Default Data Set: Clock Quality)
•
Pri1
Clock priority 1 announced by the grand master
•
Pri2
Clock priority 2 announced by the grand master
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...