Transmit TLVs -
Location
When checked the configured location information for the switch is included
in
information transmitted.
•
Transmit TLVs - PoE
When checked the configured PoE (Power Over Ethernet) information for the
interface is included in
•
Device Type
Any LLDP-MED Device is operating as a specific type of LLDP-MED Device,
which may be either a Network Connectivity Device or a specific Class of
Endpoint Device, as defined below.
A Network Connectivity Device is a LLDP-MED Device that provides access to
the IEEE 802 based LAN infrastructure for LLDP-MED Endpoint Devices
An LLDP-MED Network Connectivity Device is a LAN access device based on
any of the following technologies :
1. LAN Switch/Router
2. IEEE 802.1 Bridge
3. IEEE 802.3 Repeater (included for historical reasons)
4. IEEE 802.11 Wireless Access Point
5. Any device that supports the IEEE 802.1AB and MED extensions that can
relay IEEE 802 frames via any method.
An Endpoint Device a LLDP-MED Device that sits at the network edge and
provides some aspect of IP communications service, based on IEEE 802 LAN
technology.
The main difference between a Network Connectivity Device and an Endpoint
Device is that only an Endpoint Device can start the LLDP-MED information
exchange.
Even though a switch always should be a Network Connectivity Device, it is
possible to configure it to act as an Endpoint Device, and thereby start the
LLDP-MED information exchange (In the case where two Network Connectivity
Devices are connected together)
Coordinates Location
Object
Description
•
Latitude
Latitude
SHOULD be normalized to within 0-90 degrees with a maximum of 4
digits.
It is possible to specify the direction to either
North
of the equator or
South
of the
equator.
•
Longitude
Longitude
SHOULD be normalized to within 0-180 degrees with a maximum of 4
digits.
It is possible to specify the direction to either
East
of the prime meridian or
West
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...