User’s Manual of IGS-5225 series
169
VLAN for ports in Trunk or Hybrid mode.
•
Port Type
Ports in hybrid mode allow for changing the port type, that is, whether a frame's
VLAN tag is used to classify the frame on ingress to a particular VLAN, and if so,
which TPID it reacts on. Likewise, on egress, the Port Type determines the TPID
of the tag, if a tag is required.
■
Unaware:
On ingress, all frames, whether carrying a VLAN tag or not, get classified
to the Port VLAN, and possible tags are not removed on egress.
■
C-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 get classified to
the VLAN ID embedded in the tag. If a frame is untagged or priority
tagged, the frame gets classified to the Port VLAN. If frames must be
tagged on egress, they will be tagged with a C-tag.
■
S-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 or 0x88A8 get
classified to the VLAN ID embedded in the tag. If a frame is untagged or
priority tagged, the frame gets classified to the Port VLAN. If frames must
be tagged on egress, they will be tagged with an S-tag.
■
S-Custom-Port:
On ingress, frames with a VLAN tag with a TPID = 0x8100 or equal to the
Ethertype configured for Custom-S ports get classified to the VLAN ID
embedded in the tag. If a frame is untagged or priority tagged, the frame
gets classified to the Port VLAN. If frames must be tagged on egress, they
will be tagged with the custom S-tag.
•
Ingress Filtering
Hybrid ports allow for changing ingress filtering. Access and Trunk ports always
have ingress filtering enabled.
■
If ingress filtering is enabled (checkbox is checked), frames classified to a
VLAN that the port is not a member of get discarded.
■
If ingress filtering is disabled, frames classified to a VLAN that the port is
not a member of are accepted and forwarded to the switch engine.
However, the port will never transmit frames classified to VLANs that it is not a
member of.
•
Ingress Acceptance
Hybrid ports allow for changing the type of frames that are accepted on ingress.
■
Tagged and Untagged
Both tagged and untagged frames are accepted.
■
Tagged Only
Only tagged frames are accepted on ingress. Untagged frames are
discarded.
■
Untagged Only
Содержание IGS-5225 Series
Страница 1: ...User s Manual of IGS 5225 series 1 ...
Страница 34: ...User s Manual of IGS 5225 series 34 ...
Страница 35: ...User s Manual of IGS 5225 series 35 IGS 5225 8P2T2S IGS 5225 8P2T2S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 36: ...User s Manual of IGS 5225 series 36 IGS 5225 8P4S IGS 5225 8P4S Dimensions W x D x H 72 x 107 x 152 mm ...
Страница 37: ...User s Manual of IGS 5225 series 37 IGS 5225 4P2S IGS 5225 4P2S Dimensions W x D x H 50 x 87 8 x 135 mm ...
Страница 38: ...User s Manual of IGS 5225 series 38 IGS 5225 4T2S IGS 5225 4T2S Dimensions W x D x H 32 x 87x 135 mm ...
Страница 57: ...User s Manual of IGS 5225 series 57 Figure 2 18 Wiring DO0 and DO1 to Open Detector ...
Страница 79: ...User s Manual of IGS 5225 series 79 Figure 4 1 5 Industrial Managed Switch Main Functions Menu ...
Страница 199: ...User s Manual of IGS 5225 series 199 Figure 4 3 4 6 STP CIST Port Configuration Page Screenshot ...
Страница 265: ...User s Manual of IGS 5225 series 265 Click to undo any changes made locally and revert to previously saved values ...
Страница 288: ...User s Manual of IGS 5225 series 288 ...