57
TSP-16
5
6
7
8
5
6
7
8
A
B
C
D
E
F
8. EACH SETTING AND ADJUSTMENT
8.1 NECESSARY ITEMS TO BE NOTED
It is recommended to make a backup of user data written in this unit before repair work.
Before carrying out the repair, be sure to check the version of firmware. If the version is not the latest, update it to the latest
version.
If the following parts are replaced with new ones, carry out each item.
•
MAIN A
SS
Y
•
Check the version of firmware
•
Update to the latest firmware
•
PAD calibration
•
Restore the user data (if you can make a backup)
•
Copy the preset sample * (if you cannot make a backup of
user data)
•
MI UCOM (IC
8
005), M2 UCOM (IC
8
00
8
)
and PADB A
SS
Y
•
Check the version of firmware
•
Update to the latest firmware
•
PAD calibration
•
Performance pad part
•
PAD calibration
PADB A
SS
Y(sensor, PAD, sheet)
If you removed without having to replace PAD A
SS
Y adjustment required.
•
Touch panel
•
Touch panel test *
* If the test result is NG, carry out the touch panel calibration.
(Refer to 6.1 TE
S
T MODE PAGE 7:TOUCH PANEL TE
S
T)
* Preset sample sound source is available for download from
PDJ support site.
(Refer to 6.1 TE
S
T MODE PAGE 10:PRE
S
ET
S
AMPLE COPY)
If the product to be repaired can be started up, start it up in usual mode or test mode and change the mode to
MA
SS
S
TORAGE mode, and then connect it to PC and copy all content of T
S
P-16 that is recognized as removable disk to
the PC (make a backup). As the disk size of T
S
P-16 to be recognized is
8
GByte, ensure sufficient free space of PC to which
the data is copied.