![Pierce HUSKY 12 GPM Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/pierce/husky-12-gpm/husky-12-gpm_operation-and-maintenance-manual_1555697014.webp)
GENERAL
2-4
/ Husky 12 Foam System
© 2017 Pierce Manufacturing Inc. All Rights Reserved.
2-2.1c
Hydraulic Oil Reservoir
Figure
2-3:
Hydraulic Oil Cooler
1003
The Hydraulic Reservoir (approximately four gallon capacity) provides a reservoir for the hydraulic drive system. The
tank is sufficient size to minimize foaming of the hydraulic fluid and is located to facilitate checking level and adding
oil. Refer to
“Recommended Hydraulic Oil for Husky 12 Proportioning System”
hydraulic oil for the Husky 12 system.
2-2.1d
Hydraulic Oil Cooler
Figure
2-4:
Hydraulic Oil Cooler
1004
To Hydraulic
Pump
Shut-off Valve (in-line
position is OPEN)
Hydraulic Oil
In/Out
Cooling Water
In/Out