Question
Reason for Question
Test Procedure
B. Does the foam pump engage?
To isolate the problem
from between electrical
and mechanical failures.
NOTE:
You must be flowing water for
the foam pump to operate.
Turn the foam percent up and listen for the
foam pump to engage.
Question
Reason for Question
Test Procedure
C. Tank fill option - look to see if
the selector valve is in the
TANK FILL mode.
If the tank fill valve is
open, all of the foam
concentrate will circulate
between the foam pump
and the foam tank, with
little or none being
injected.
Remove the tube from the outlet of the tank fill
valve. Operate the foam system. If foam
concentrate is discharged, the tank fill valve is
open.
NOTE:
In the TANK FILL mode, the
tank to pump valve should be
closed automatically. If this
does not occur, check for a
bad switch at the selector
valve.
Question
Reason for Question
Test Procedure
D. Is the foam injection check
valve stuck in the CLOSED
position?
Foam concentrate cannot
reach the foam injection
manifold if the check valve
is stuck closed.
Check by visual inspection, or the foam pump
may make a squealing noise when the pump
goes into the relief mode.
No
Yes
Yes
No
Replace the foam injection
check valve.
No
End