GENERAL
The foam pump also has a pressure relief valve that recirculates the foam from the discharge side to the inlet side
in the case of an obstruction or overpressure situation. The foam pump speed and operation are monitored by a
foam pump transducer located in the hydraulic end of the pump assembly.
The foam concentrate pump is self-priming and has the capability to draw foam concentrate from external supplies
such as drums or pails. The foam concentrate pump has a maximum capacity of 12 GPM with all types of foam
concentrates with a viscosity at or below 6000 cps including protein, fluoroprotein, AFFF, FFFP, or AR-AFFF.
2-2.2d
Foam Selector Valve
Figure
2-8:
Foam Selector Valve
1009
The Foam Selector Valve is a 2-way, quarter-turn ball valve that directs the foam for foam injection (normal
operation) or tank filling. A “CHECK SELECTOR VALVE” message is displayed by the control head in the event that
the valve is not in the correct position for the operation selected.
From Foam Pump
Tank Fill Hose*
Injection Hose
*A foam selector valve
with the tank fill option is
shown. On units without
the tank fill option, the fill
hose will be routed
directly to tank.