4-6.1a
Set Automatic Flush Time
MODE SELECT
→
SETUP SELECTION
→
SETUP
→
PARAMETERS
NOTE:
•
An automatic flush occurs whenever foam source is switched from a Class A to Class B foam
or vice-versa.
•
The factory default setting is 10-15 seconds.
Figure
4-7:
Parameters Screen Flush Timer
1570B
1.
While in the Parameters screen, press ARROW UP or ARROW DOWN to select Flush/Fill, then press ENTER.
2.
Press ARROW UP or ARROW DOWN to set the desired flush duration.
3.
Press ENTER to accept new default value.
4-6.1b
Auto Start
MODE SELECT
→
SETUP SELECTION
→
SETUP
→
PARAMETERS
NOTE:
The auto start option will automatically turn the foam system on the first time the water pump is
engaged. The option must have sensors installed in the foam system hydraulics and have additional
wiring installed in order to function.
Figure
4-8:
Parameters Screen Auto Start
1570A
1.
While in the Parameters screen, press ARROW UP or ARROW DOWN to select Auto Start, then press ENTER.
2.
Press ARROW UP or ARROW DOWN to toggle between ON and OFF options.
3.
Press ENTER to accept the selection.