MAINTENANCE
4-6
/ Husky 12 Foam System
© 2017 Pierce Manufacturing Inc. All Rights Reserved.
4-6.
Set Up Mode
4-6.1
Parameters
MODE SELECT
→
SETUP SELECTION
→
SETUP
→
PARAMETERS
The Parameters screen allows the user to adjust Flush Timer, Auto Start, Units (UOM), Language, and Backlight.
Figure
4-5:
Setup
Screen
Activation
1557E, 1568A, 1569A
1.
From the normal operation screen (Foam Pump Not Running), navigate to the SETUP screen. Refer to
2.
Use the UP/DOWN buttons to highlight Parameters and press ENTER to bring up the PARAMETERS screen.
Figure
4-6:
Parameters
Screen
1570B
NOTE:
The English/Metric screen provides the option of reading the flow in GPM or LPM.
3.
Using the UP/DOWN buttons, highlight the desired selection.
4.
Press the ENTER button to activate the selection.
5.
Using the UP/DOWN buttons, toggle through the list of possible choices.
6.
Press the ENTER button to save the setting.
7.
Repeat steps 3 through 6 as necessary to update additional settings.
8.
When complete, press the PAGE button 4 times to get back to the home screen.
HOLD ENTER AND
PRESS ARROWS
PRESS
PAGE
HOLD 5
SECONDS
SCROLL TO
SETUP
SCROLL TO
SETUP