Содержание M 360

Страница 1: ...nstructions February 2015 M 360 Firebox INSTRUCTION FOR INSTALLATION USE AND MAINTENANCE Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 Email info robeys co uk www robeys co uk ...

Страница 2: ...2 M360 Firebox Installation Instructions February 2015 ...

Страница 3: ...is installed is properly ventilated while the stove is lit In the event of malfunctioning the fuel supply will be stopped Restart the stove only after having eliminated the cause of the malfunction Stop using the product in the event of fault or malfunctioning Stove operation can result in surfaces handles flue pipe and glass becoming extremely hot When the appliance is in operation only touch the...

Страница 4: ...lectricity supply 24 5 2 Flue installation 24 5 3 Hood installation 27 5 4 Positioning the appliance 27 5 5 Positioning the edging trim 30 6 0 USE 31 6 1 Fuel 31 6 2 Smoke damper regulation 32 6 3 Preset combustion air 32 6 4 Lighting for the first time 32 6 5 Lighting 33 6 6 Opening the glass operating mode 33 6 7 Operation under adverse weather conditions 33 6 8 Overheating and extinguishing 33 ...

Страница 5: ...ity Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Documen...

Страница 6: ... be taken if required seeking expert advice if necessary If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted in place of an open fire then the chimn...

Страница 7: ...installed to provide combustion air The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insulated metal chim...

Страница 8: ...er the installer should have shown you how to operate the stove correctly CO Alarm Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accident...

Страница 9: ...ney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately Do not relight the stove until the chimney and flue ways have been cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently In accordance with current Buildi...

Страница 10: ...iven in the paragraph MINIMUM SAFETY DISTANCES and to all the indications below CHIMNEY POT FLUE WAY CHECK FLOOR FOR LOAD BEARING CAPACITY CONNECTION TO FLUE DOUBLE POLE SWITCH AND EMERGENCY SWITCH IN FLOOR CABLE DISTRIBUTION MAX ALLOWED DISTANCE 5 METRES INTERNAL AIR INTAKE UNDER FLOOR DUCTING FRESH AIR INTAKE HOOD SUSPENDED FROM CEILING MINIMUM SAFETY DISTANCES TO COMBUSTIBLE SURFACES FIG 1 ...

Страница 11: ...y an air gap or suitable insulating material Fig 3 be of uniform internal section preferably round Square or rectangular sections must have rounded corners with a radius of at least 20 mm and a maximum ratio between the sides of 1 5 Fig 3 4 5 the walls must be smooth if possible and without narrowing bends must be regular and without discontinuity Fig 6 It is forbidden to make fixed or mobile aper...

Страница 12: ... matter into the flue and to ensure that in the event of winds from all directions and angle discharge of the combustion products is assured chimney stack with down draught cowl Recommended distances for correct chimney operation To ensure trouble free operation of the chimney and allow correct dilution of the products of combustion in the air the chimney stack must be installed at the distances g...

Страница 13: ...e It can not be in a vacuum in relation to the outside environment due to the effect of contrary draught caused by the presence in the room where the fireplace is installed of another appliance or an extractor device Do not use two stoves a fireplace and a stove a fireplace and a wood fired cooking range etc in the same environment since the draught of one could affect the draught of the other Dev...

Страница 14: ...cific weight of at least 245 kg m3 with limit working temperature of at least 1000 C Thermal conductivity X 400 C 0 1 W mK Thickness as shown in the figures in the paragraph MINIMUM SAFETY DISTANCES If the insulating material is not lining the walls it must be fixed all over the surface of the walls with anchorage points every 30 cm Material coded AGI Q132 or DIN 18895 is allowed for heat insulati...

Страница 15: ... surface and a clean cut linear front to the firebox offer an unparalleled view of the fire The combustion air is self regulating and ensures that the glass remains clean all the way round The simple controls for opening and closing the electrically operated glass panels ensure that this quality product is reliable and easy to use in all safety No Description Qty Aluker grate 4 Ash drawer 1 Grate ...

Страница 16: ...ystem closure Primary and secondary air control calibrated Smoke damper adjustable Smoke outlet top Heating natural convection 2 4 PRODUCT IDENTIFICATION DATA Every product is identified by a rating plate showing the model and the performance of the appliance as well as a plate giving the serial number One rating identification plate is located on the bottom shield under the ash drawer Fig 16 and ...

Страница 17: ...S OF INSTALLATION Fresh air intake recommended minimum section cm2 300 Combustion air flow rate with open intake m3 h Convective air inlet outlet recommended minimum section cm2 300 400 Maximum power rating W 60 Electrical power supply stand by W 5 Electrical power supply V 230 Frequency Hz 50 These data are obtained using beech wood with moisture content below 20 and with intervals between stokin...

Страница 18: ...18 M360 Firebox Installation Instructions February 2015 2 6 DIMENSIONS Non Combustible Ceiling e g concrete ...

Страница 19: ...19 M360 Firebox Installation Instructions February 2015 ...

Страница 20: ...20 M360 Firebox Installation Instructions February 2015 2 7 WIRING DIAGRAM ...

Страница 21: ...21 M360 Firebox Installation Instructions February 2015 PCB INTERNAL CONNECTIONS CMF CMF ...

Страница 22: ...an be used for installing the M360 The examples are given purely as an indication solely for the purpose of identifying the type of ceiling roof with which the relative flue pipe should be associated Every self supporting pipe will be sized as required except for solution number 1 standard solution Ceiling roof height is given as the height H measured along the axis of the hole in line with the ce...

Страница 23: ...re are no persons or things within the area Carefully read all the information contained in the section GENERAL RULES before installing the fireplace Unpack the fireplace Remove the supplied accessories from the firebox as well as the packaging elements used to wedge parts during transportation After having removed the packaging from the appliance remove the grid B the ash box C and lastly the Alu...

Страница 24: ...efore it reaches the end stop because the relative sensors are not active and the guide system could be damaged see REPLACING THE CONTROL UNIT ASSEMBLY Under normal conditions it is essential to keep the emergency circuit on wires F7 white and F8 blue closed see WIRING DIAGRAM Even if the key operated switch is not installed it is essential that the relative cables as laid as far as the control pa...

Страница 25: ...ts of the split ring collar C are joined together using the screws and washers provided in the kit Fig 27 The screws should not be fully tightened but just enough to support the pipe temporarily Check that the end pipe flange is exactly 224 cm from the ground Check that the flange is level and perfectly vertical using a precision spirit level Fig 28 Fasten the whole collar assembly using the screw...

Страница 26: ...plit ring collar If this is the case ask the customer to have suitable building work carried out that has been adequately designed and approved by qualified professionals Drill holes Ø5mm in line with the 4 holes marked on the upper split ring collar The split ring collar and the pipe should be drilled together Fully tighten the 4 self tapping screws M6 G provided in the kit Fig 32 The above steps...

Страница 27: ... procedure so as not to damage the enamel of the hood or the pipe Fig 33 The hood is fixed using the six screws TSPEI M5x16 C provided in the kit taking great care in fully tightening them Fig 34 5 4 POSITIONING THE APPLIANCE Raise the base A towards the hood B only using the indicated lifting eyebolts to lift it Fig 35 The product must be lifted using the indicated eyebolts Do not hold the produc...

Страница 28: ...lightly The best height from the ground of the base with fully screwed on feet will be 60 cm Avoid except in particular cases raising it too much from the ground The height of the grate from the ground must not be more than 61 cm After having positioned the appliance remove the locating template E and the fastened self tapping screws H Fig 39 Install the smoke baffle plate I inside the hood B by i...

Страница 29: ...the distances are equal If the base is centred in relation to the hood product operation and performance is at its best and the glass becomes less dirty Having checked that the base is centred in relation to the hood anchor the base to the floor using the brackets S and masonry plugs T if possible or spread some silicone under the brackets Fig 43 T he brackets must adhere to the floor with the app...

Страница 30: ... inside of the edging trim D When the buttons B have been installed reconnect them to the cable end connector E Enter the maintenance mode see MAINTENANCE MODE and lower both glass panels Fit the edging trim D so that the buttons B straddle the line where the glass panels meet It should be remembered that the top of the edging trim must be at a height of 60 cm from the ground see DIMENSIONS Before...

Страница 31: ...he summer June July since woods are cut down mostly in the autumn and you can therefore be sure that the timber has already been seasoned for approximately 1 year Firewood can be classified in two qualities good and mediocre or poor This classifica tion is according to the heat yield of the wood the longest flame time it provides its com position and density Good fuels Recommended timber comes fro...

Страница 32: ...TIME Before lighting remove the supplied accessories see ACCESSORIES AND EQUIPMENT paragraph and flammable elements from the grate or from the ash tray pan If provided in the kit it is very important to remove the paint spray can which could explode There are two important stages when lighting the appliance for the first time the operating test and start up 1 Operating test Before carrying out the...

Страница 33: ...imit switches is reached when normal speed is resumed CLOSING keep the button pressed down the glass starts to rise and automatically goes to the closed position which is confirmed by a double beep The upward movement of the glass may be stopped by releasing the button The glass will stop moving immediately and the direction of movement will be reversed emergency reversal In the operating mode it ...

Страница 34: ... stack the fresh air intake the appliance hearth correct position of the plates the ash tray the grate and grid smoke baffle plates smoke dampers etc the ventilation system apertures air ducts grilles if installed Check that the automatic door closing system and the air dampers if installed are in proper working order Maintenance of all the above heating system must be carried out at least once a ...

Страница 35: ...mpletely non toxic and is heat resistant up to 1400 C In spite of its considerable strength it is not recommended that you throw large pieces of wood forcefully against the bricks Aluker darkens when the fireplace is first lit but returns to its natural colour gradually as the bricks warm up Some advice for optimum use of Aluker bricks don t use water to put out the fire leave the bricks to cool b...

Страница 36: ... the appliance may now be fully accessed When refitting the parts before tightening the fastening screws check that the grate base is centred in relation to the glass panels otherwise they could be scratched on the inside during movement 7 10 REPLACING THE GLASS Before replacing any damaged glass identify and remedy the cause of break age Enter maintenance mode see MAINTENANCE MODE Protect hands w...

Страница 37: ...ed to the glass frame The new glass panel complete with gasket is fitted into place between the glass panel clamp G and the frame H Fig 51 Check that the fitted gaskets do not become separated or overlap each other The signs on the glass must be towards the top Rest the side edge of the glass panel on the internal rebate of the collar I checking that there is full contact in the points where the g...

Страница 38: ...ect the Minifit connector see WIRING DIAGRAM from the receptacle coming out of the control unit B Fig 54 Disconnect the Molex 4 pin connector that is used for connecting the control buttons Use a screwdriver to remove the 4 screws C and washers D Fig 55 Take out the control unit B complete with support E and replace it with the new one Reconnect all the cables following the steps described above i...

Страница 39: ...owever use the grease to excess should grease accumulate on the lower parts of the guide we recommend that all excess be removed The lubricant has properties of excellent adherence and viscosity high resistance to temperature and a very low capacity of mixing with dust or ash It is therefore recommended that you only use the lubricant we supply optional Other unsuitable lubricants could seriously ...

Страница 40: ... Nor should you activate the ventilation system until the odorous gases have dispersed This problem can be dealt with by simply airing the room 7 14 REMOVING THE SMOKE BAFFLE PLATES The fireplace is fitted inside above the grate with a baffle plate which has the function of deflecting the route taken by the smoke thereby increasing the heat exchange surface area The baffle plate rests on the suppo...

Страница 41: ...ance or use of other than original spare parts invalidates the warranty and relieves the manufacturer of all and any liability The manufacturer shall not be liable for any problems caused by lack of or inefficient maintenance or by failure to comply with the instructions in the product installation and operating guide This instruction booklet contains all the useful information for installation op...

Страница 42: ...42 M360 Firebox Installation Instructions February 2015 ...

Страница 43: ...43 M360 Firebox Installation Instructions February 2015 ...

Страница 44: ...44 M360 Firebox Installation Instructions February 2015 ...

Страница 45: ...45 M360 Firebox Installation Instructions February 2015 ...

Страница 46: ...46 M360 Firebox Installation Instructions February 2015 ...

Страница 47: ...47 M360 Firebox Installation Instructions February 2015 ...

Страница 48: ...ruary 2015 Product serial number to be quoted when requesting service from the Gruppo Piazzetta After Sales Service Centre ROBEYS LTD GOODS ROAD INDUSTRIAL ESTATE BELPER DERBYSHIRE DE56 1UU TEL 01773 820940 FAX 01773 820477 EMAIL INFO ROBEYS CO UK ...