M360 Firebox Installation Instructions
February 2015
1.4 FRESH AIR INTAKE
To ensure trouble-free operation the fireplace must have the necessary air
available for combustion and can be provided through a fresh air intake.
The fresh air intake must:
have a total free cross section at least equal to the size given in the paragraph
"TECHNICAL DATA";
be protected by a grille or suitable guard provided it does not reduce the
minimum recommended section;
be in a position whereby it cannot be obstructed;
The airflow necessary for the fire may be obtained in this ways:
through a fresh air intake direct into the room of installation.
with ducting through pipes direct to the installation room, going under the floor. Also
increase the recommended minimum free cross section by at least 15%; (Fig. 12)
Combustion air must not be taken from adjacent rooms used as a garage or a
combustible materials store or for activities posing a fire hazard.
1.5 INSTALLATION ENVIRONMENT
The appliance should be installed in a location which allows safe and convenient use as well as easy maintenance. If the product being installed requires
an electrical socket, the room must also be provided with an earthed power supply in accordance with current regulations. The room where the appliance
is to be installed must comply with the following requirements.
It can not be used as a garage, store for combustible material or for activities with a risk of fire.
It can not be in a vacuum in relation to the outside environment due to the effect of contrary draught caused by the presence in the room
where the fireplace is installed of another appliance or an extractor device.
Do not use two stoves, a fireplace and a stove, a fireplace and a wood-fired cooking range, etc. in the same environment, since the draught
of one could affect the draught of the other.
Devices suitable for cooking food with relative hoods without an extractor fan may only be used in kitchens.
Gas appliances of type C are allowed (refer to current legislation and regulations in the place of installation)
Gas appliances of type B are not allowed (refer to current legislation and regulations in the place of installation).
The fireplace must not be used simultaneously with collective type ventilation ducts with or without extractor fan, other devices or other
appliances such as: forced ventilation systems or other heating systems using ventilation to change the air. Such systems could cause a
vacuum in the environment of installation even if installed in adjoining or communicating rooms.
The fireplace must not be used: in stairwells except in buildings with no more than two apartments; in corridors for common use; in
bedrooms; in bathrooms or shower-rooms.
1.6 LOAD-BEARING CAPACITY OF THE FLOOR
Check the load-bearing capacity of the floor by adding together: the weight of the protections (lining walls), insulating materials, surround (given in the
surround instruction booklet) and the fireplace (given in the paragraph
"TECHNICAL DATA").
If the floor has an unsuitable load-bearing capacity, take adequate countermeasures.
Содержание M 360
Страница 2: ...2 M360 Firebox Installation Instructions February 2015 ...
Страница 18: ...18 M360 Firebox Installation Instructions February 2015 2 6 DIMENSIONS Non Combustible Ceiling e g concrete ...
Страница 19: ...19 M360 Firebox Installation Instructions February 2015 ...
Страница 20: ...20 M360 Firebox Installation Instructions February 2015 2 7 WIRING DIAGRAM ...
Страница 21: ...21 M360 Firebox Installation Instructions February 2015 PCB INTERNAL CONNECTIONS CMF CMF ...
Страница 42: ...42 M360 Firebox Installation Instructions February 2015 ...
Страница 43: ...43 M360 Firebox Installation Instructions February 2015 ...
Страница 44: ...44 M360 Firebox Installation Instructions February 2015 ...
Страница 45: ...45 M360 Firebox Installation Instructions February 2015 ...
Страница 46: ...46 M360 Firebox Installation Instructions February 2015 ...
Страница 47: ...47 M360 Firebox Installation Instructions February 2015 ...