EN 60
3139 785 32804
Firmware Upgrading & Diagnostic Software
5.
Nucleus Name
DS_SYS_LowPowerStandby
Nucleus Number
1239
Description
Send wakeup reason to ASP and set the set to low power standby.
Technical
-
Set up ASP
-
Send wakeup reason to ASP
-
Send low power standby command to ASP
Execution Time
Vary (Maximum time will depend on the relative timer used)
User Input
-
wakeup reason - the wakeup reason for the DB to power up
-
timer - relative timing for the DB to power up if wakeup reason 1 or 3 is
chosen
Error
Number
Description
123901
Invalid data was given by the user
123902
Failed to communication to ASP
Example
DS:> 1239
Wakeup reason from Low Power Standby
1) timer only
2) local key or RC pressed only
3) any reason
or press 'a' to abort
1
Enter time to wake up from low power standby.
Range 1 - 5 mins:
1
Entering low power standby
Nucleus Name
DS_SYS_DivxModelIdSet
Nucleus Number
1240
Description
Sets the Divx Model Id in NVRAM.
Technical
-
Initialize the NVM interface.
-
Read the NVRAM CONFIG section into RAM
-
Store the Divx model id into the CONFIG section in RAM
-
Validate the CONFIG section in RAM
-
Write the CONFIG section in RAM back into the non-volatile storage.
Execution Time
Less than 2 seconds
User Input
-
16-bit word containing the 12-bit Divx model Id.
-
For example :
o
0x3031 (means Low Byte : 0x30 and High Byte 0x31)
Error
Number
Description
124001
Validate CONFIG section failed
124002
Cannot read CONFIG section
124003
Invalid user parameters
124004
Error initializing NVRAM interfaces
Example
DS:> 1240 0x3031
124000:
Test OK @
Nucleus Name
DS_SYS_DivxModelIdGet
Nucleus Number
1241
Description
Retrieves the Divx Model Id from NVRAM.
Technical
-
Read the CONFIG section from NVRAM
-
Check the header information of the CONFIG section to ensure that it is
Version 4
-
If Version 4 is detected, proceed to read and display the High Byte and
Low byte of the Divx Model Id.
Execution Time
Less than 2 seconds
User Input
None.
Error
Number
Description
124101
Section version not Version 4
124102
Cannot read CONFIG section
124103
Error initializing NVRAM interfaces
Example
DS:> 1241
124100: Divx model id high byte = 0x31, low byte = 0x30
Test OK @
Nucleus Name
DS_SYS_DivxModelIdSet
Nucleus Number
1240
Description
Sets the Divx Model Id in NVRAM.
Technical
-
Initialize the NVM interface.
-
Read the NVRAM CONFIG section into RAM
-
Store the Divx model id into the CONFIG section in RAM
-
Validate the CONFIG section in RAM
-
Write the CONFIG section in RAM back into the non-volatile storage.
Execution Time
Less than 2 seconds
User Input
-
16-bit word containing the 12-bit Divx model Id.
-
For example :
o
0x4BF0 (means Low Byte : 0x4B and High Byte 0xF0)
Error
Number
Description
124001
Validate CONFIG section failed
124002
Cannot read CONFIG section
124003
Invalid user parameters
124004
Error initializing NVRAM interfaces
Example
DS:> 1240 0x4BF0
124000:
Test OK @
Nucleus Name
DS_SYS_DivxModelIdGet
Nucleus Number
1241
Description
Retrieves the Divx Model Id from NVRAM.
Technical
-
Read the CONFIG section from NVRAM
-
Check the header information of the CONFIG section to ensure that it is Version 4
-
If Version 4 is detected, proceed to read and display the High Byte and Low byte of
the Divx Model Id.
Execution Time
Less than 2 seconds
User Input
None.
Error
Number
Description
124101
Section version not Version 4
124102
Cannot read CONFIG section
124103
Error initializing NVRAM interfaces
Example
DS:> 1241
124100: Divx model id high byte = 0xF0, low byte = 0x4B
Test OK @
http://www.jdwxzlw.com/?fromuser=华盛维修