Hardware setup
Philips Communication, Security & Imaging
4-3
Monitor connections
Connect the unit to the monitors using 75-ohm video coaxial cables with BNC
connectors. The unit provides a 1Vpp CVBS signal.
If the monitor has a loop-through connection and you are not using the loop-
through output, then select the 75-ohm impedance setting on the monitor. If the
monitor's loop-through output is connected to an additional device, the device's
termination is set to 75 ohms and the monitor's termination is set to high
impedance. (Note that this is not necessary on devices with automatic
termination.)
Specifications
Output signal:
Composite video 1Vpp, 75 Ohm, Sync. 0.3Vpp ±10%
Resolution:
720 x 576 PAL, 720 X 484 NTSC
Connector type:
BNC
Console port connection
The serial RS232 console port connector is used to connect a PC to the unit for
configuration or service purposes. Use a null-modem cable to connect the serial
port of the PC to the unit. The Baud rate can be selected in the menu system
Specification
Connector type:
9-pole D-type male connector
Maximum input voltage:
±25V
Communicaton protocol:
Output signals according EIA/TIA-232-F
RS232 console port socket.
Signal Name:
Pin no.
Description
DCD_in
1
Carrier detection signal (not used).
RX
2
RS232 receive signal
TX
3
RS232 transmit signal
N/C
4
No Connection
System Ground
5
System Ground
N/C
6
No Connection
RTS
7
RS232 request to send signal
CTS
8
RS232 clear to send signal
N/C
9
No Connection
5
1
6
9
Panel view
Содержание Divar
Страница 1: ...DIVAR DIGITAL VERSATILE RECORDER Installation Manual www philipscsi com ...
Страница 40: ...Hardware setup 4 10 Philips Communication Security Imaging ...
Страница 62: ...Using the Configuration Tool 6 8 Philips Communication Security Imaging ...
Страница 70: ...Menu default values 7 8 Philips Communication Security Imaging ...
Страница 74: ...8 4 Philips Communication Security Imaging ...