Video loss alarm
If the loss of a video signal causes an alarm:
Monitor A or B can be set up to show the video loss signal.
• Monitor A switches to multiscreen view. The lost camera signal is displayed
as a black cameo with the video loss message. The border around the camera
with the video loss is red. An alarm status message is displayed.
• Monitor B: Sequenced display of cameras that do not have video loss.
• The alarm beeper sounds.
• The video loss
and the
indicators flash.
Acknowledging a video loss alarm
1. Press the acknowledge key
to acknowledge a video loss alarm.
> The beeper is silent.
> The video loss
and
indicators are no longer lit.
> The alarm status message disappears.
> The last-used view mode is restored.
If the camera with video loss is visible, the black cameo and the video loss
message continue to be displayed as long as there is no video present.
If an alarm is not acknowledged, the beeper, and the video loss
and
indicators switch off after the dwell time but the alarm still needs to be
acknowledged.
If auto-acknowledge is enabled, the beeper, and the video loss
and
indicators switch off after the dwell time.
Multiple alarms
Monitor A switches to multiscreen view if more than one alarm occurs. The
latest alarm status message is always shown. Pressing the acknowledge key
deactivates all alarms.
Disk-full alarm
A disk-full alarm message is displayed on monitor A and the alarm beeper
sounds.
1. Press the acknowledge key
to acknowledge the disk-full alarm.
> The beeper is silent.
> The disk-full alert message disappears.
2. To avoid losing information, take corrective action to free disk space (for
example, archive and delete some recordings).
Содержание Divar
Страница 1: ...DIVAR DIGITAL VERSATILE RECORDER Installation Manual www philipscsi com ...
Страница 40: ...Hardware setup 4 10 Philips Communication Security Imaging ...
Страница 62: ...Using the Configuration Tool 6 8 Philips Communication Security Imaging ...
Страница 70: ...Menu default values 7 8 Philips Communication Security Imaging ...
Страница 74: ...8 4 Philips Communication Security Imaging ...