0.9 BDL3245E/BDL4245E/BDL4645E
32”/42”/46” FHD LCD PUBLIC DISPLAY
2011-07-01 PHILIPS Page 9 of 38
MMD Confidential
2.4 Service mode
Detailed technical specification refers to Service delta technical specs.
•
Software
Update:
¾
Through RS-232, RJ-45 and USB
The system should have the recovery mechanism when updating failure
2.5 Power Supply
2.5.1 Power supply features
•
AC line voltage range -
90Vac ~ 264Vac.
•
AC line frequency range -
50-60 Hz
±
3 Hz.
•
DC tact switch -
Minimal power consumption when switch off
•
AC mains switch -
No power consumption when switch off.
•
Inrush current -
< 40A at 240Vac when cold start.
•
Leakage current -
< 0.5mA at 240Vac.
•
Power factor correction -
According to EN61000-3-2
2.5.2 Power consumption
•
Normal on -
32” 140W
(typical),
160W
(max.)
•
42” 210W (typical), 260W(max.)
•
46” 220W (typical), 270W(max.)
When Lan turn off power consumption spec:
•
Power saving (LAN off) -
< 1W
•
Power saving (schedule ON) < 2W
•
Power
saving
<
2W
•
Switch off (DC off) or standby - < 0.5W,remote off
•
Switch off (AC mains) -
< No power consumption.
•
Recovery times 15sec for change mode and power start time.
When Lan turn on power consumption spec:
•
Power saving < 5W
•
DC OFF < 3W (Lan ON Status)
•
Recovery times 15sec for change mode and power start time.
For OPS module
OPS module no need to judge thermal temperature just qualification for functionality
2.5.3 Display DPM standby
z
DPM -
The Display enters DPM off (sleep) mode when no H&V sync, one of H-
sync / V-sync input or digital clock is absent. “No Signal” message appears before
entering DPM mode.
And then, show “
Going to Deep Sleep
”
message for 3
seconds. A delay of 3 seconds before entering the power saving state is
required to avoid misunderstanding of display resolution and timing mode
changes.
Содержание BDL4245E/00
Страница 35: ...35 5 Block Diagram 5 1 Scaler Board ...
Страница 78: ...78 78 3 Remove all the screws as follow ...
Страница 79: ...79 4 Remove the main frame from the panel ...
Страница 83: ...83 3 Remove all the screws as follow ...
Страница 84: ...84 84 4 Remove the main frame from the panel ...
Страница 89: ...89 3 Set the parameters as below figure ...
Страница 91: ...91 6 Click Commands batch to load the file isp_psi_ext txt ...
Страница 95: ...95 ...
Страница 97: ...97 ...
Страница 100: ...100 100 5 Click Auto to upgrade 6 Update processing ...
Страница 101: ...101 7 Upgrade successfully 6 Troubleshooting Not connected error The way to cure it by select correct ISP Target ...
Страница 104: ...104 104 2 Tick the Analog DVI and click Loadfile to set the parameters 3 Select the EDID folder ...
Страница 137: ...137 ...
Страница 138: ...138 138 15 Monitor Exploded View ...
Страница 139: ...139 ...
Страница 140: ...140 140 ...
Страница 144: ...144 144 17 General Product Specification Please refer to the Product Specification the next page ...