EN - 1
08/2015
Copyright © 2015, Fast ČR, a. s.
Setting salt consumption
The dishwasher is designed to enable the adjustment of salt consumption on the basis of the hardness of the
water used. This should optimise and adapt the level of salt consumption.
Table for setting up water hardness
Hardness level
of Water
dH (German
unit)
dF (French
unit)
dE (English
unit)
Water hardness setting
indicator
1
0 – 5
0 – 9
0 – 6
The display shows L1.
2
6 – 11
10 – 20
7 – 14
The display shows L2.
3
12 – 17
21 – 30
15 – 21
The display shows L3.
4
18 – 22
31 – 40
22 – 28
The display shows L4.
5
23 – 31
41 – 55
29 – 39
The display shows L5.
6
32 – 50
56 – 90
40 – 63
The display shows L6.
NOTE:
Water hardness is factory set to 3.
Set the water hardness according to the value on the testing strip.
1. Press and hold down the program selection (4) and delayed start (5) buttons for approximately 3 seconds.
The message "Keep pressing ..x" (Hold down for time ..X) will appear on the display, showing the time that
the buttons still need to be pressed. As soon as number "0" appears on the display, the "Settings Menu"
(Settings menu) will be shown.
2. Using the up (7) / down (8) buttons, select from the menu item "2. Water Hardness“ (2. Water hardness: X).
In this case "X" represents value: L01, L02, L03, L04, L05 or L06.
3. Then press the confi rm button (3) and the "X" value will start to fl ash on the display. Using the Up (7) /
down (8) buttons, select the water hardness value.
4. Press the confi rm button (3) to save the settings. "Stored" (Saved) will appear on the screen.
Your setting will be stored and the display will automatically return to the water hardness settings menu.
To exit from the menu, hold down the program selection (4) and delayed start (5) buttons for approximately
3 seconds or select the last item in the menu "8. Exit Menu“ (8. Exit menu) and confi rm with the confi rm button (3).
CAUTION!
If your dishwasher does not have a water softening system, you can skip this chapter.
Содержание PD 125 IQ
Страница 1: ...DISHWASHER USER S MANUAL PD 125 IQ...