background image

 

26

 

   DISPOSAL OF UNIT 

 

(English) 

Information on Disposal for Users of Waste Electrical & Electronic Equipment 

(private households)

 

 
This symbol on the products and/or accompanying documents means that 
used electrical and electronic products should not be mixed with general 
household waste. 
For proper treatment, recovery and recycling, please take these products to 
designated collection points, where they will be accepted on a free of charge 
basis. Alternatively, in some countries you may be able to return your products 
to your local retailer upon the purchase of an equivalent new product. 
Disposing of this product correctly will help to save valuable resources and 

prevent any potential negative effects on human health and the environment which could otherwise 
arise from inappropriate waste handling.  Please contact your local authority for further details of 
your nearest designated collection point. 
Penalties may be applicable for incorrect disposal of this waste, in accordance with national 
legislation. 
 

For business users in the European Union 

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for 
further information. 

 

Information on Disposal in other Countries outside the European Union 

This symbol is only valid in the European Union. 
If you wish to discard this product, please contact your local authorities or dealer and ask for the 
correct method of disposal. 

 
 

(German) 

Benutzerinformationen zur Entsorgung von elektrischen und elektronischen 

Geräten (private Haushalte)

 

 
Dieses Symbol auf Produkten und/oder begleitenden Dokumenten bedeutet, 
dass verbrauchte elektrische und elektronische Produkte nicht mit 
gewöhnlichem Haushaltsabfall vermischt werden sollen. 
Bringen Sie zur ordnungsgemäßen Behandlung, Rückgewinnung und 
Recycling diese Produkte zu den entsprechenden Sammelstellen, wo sie ohne 
Gebühren entgegengenommen werden. In einigen Ländern kann es auch 
möglich sein, diese Produkte beim Kauf eines entsprechenden neuen Produkts 
bei Ihrem örtlichen Einzelhändler abzugeben. 

Die ordnungsgemäße Entsorgung dieses Produkts dient dem Umweltschutz und verhindert mögliche 
schädliche Auswirkungen auf Mensch und Umgebung, die aus einer unsachgemäßen Handhabung 
von Abfall entstehen können. Genauere Informationen zur nächstgelegenen Sammelstelle erhalten 
Sie bei Ihrer Gemeindeverwaltung. 
In Übereinstimmung mit der Landesgesetzgebung können für die unsachgemäße Entsorgung dieser 
Art von Abfall Strafgebühren erhoben werden. 
 

Für Geschäftskunden in der Europäischen Union 

 
Bitte treten Sie mit Ihrem Händler oder Lieferanten in Kontakt, wenn Sie elektrische und 
elektronische Geräte entsorgen möchten. Er hält weitere Informationen für sie bereit. 
 

Informationen zur Entsorgung in anderen Ländern außerhalb der Europäischen 

Union 

 
Dieses Symbol ist nur in der Europäischen Union gültig. 
Bitte treten Sie mit Ihrer Gemeindeverwaltung oder Ihrem Händler in Kontakt, wenn Sie dieses 
Produkt entsorgen möchten, und fragen Sie nach einer Entsorgungsmöglichkeit. 

 

Содержание MPR-S163 Series

Страница 1: ...es Please read the operating instructions carefully before using this product and keep the operating instructions for future use See page 32 for all model numbers Operating Instructions Pharmaceutical...

Страница 2: ......

Страница 3: ...TTING P 17 Setting of high temperature alarm P 17 Setting of low temperature alarm P 18 SETTING OF DELAY OF DOOR ALARM P 19 SETTING OF ALARM BUZZER RECOVERY P 20 OPERATION CHECK AFTER RECOVERY P 21 RE...

Страница 4: ...ent of performance or functions Contact our sales representative or agent if any page of the operating instructions is lost or page order is incorrect Contact our sales representative or agent if any...

Страница 5: ...her person Precautions are illustrated in the following way WARNING Failure to observe WARNING signs could result in a hazard to personnel possibly resulting in serious injury or death CAUTION Failure...

Страница 6: ...wer supply outlet is not grounded it will be necessary to install a ground by qualified engineers Never ground the unit through a gas pipe water main telephone line or lightning rod Such grounding may...

Страница 7: ...e electric shock or fire Do not position this unit and the other unit so that it is difficult to operate the disconnection of the power supply plug Failure to disconnect the power supply plug may caus...

Страница 8: ...operation after power failure or turning off of power switch The stored items may be damaged due to the change of setting Be careful not to tip over the unit during movement to prevent damage or injur...

Страница 9: ...C Maximum relative humidity 80 for temperature up to 31 o C decreasing linearly to 50 relative humidity at 40 o C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltag...

Страница 10: ...8 Rear side REFRIGERATOR COMPONENTS 2 17 19 18 13 1 MPR S163 10 8 3 2 6 4 9 11 12 5 7 18 19 17 MPR S313 1 3 2 4 6 5 7 10 11 12 13 8 9 16 MPR S163 PE MPR S313 PE only 15 14 6 Power supply cord...

Страница 11: ...r a temperature recorder Location for an optional temperature recorder page 30 10 Key lock Insert the key and turn to the clockwise 180o with pressing into the head of lock when lock the doors 11 Shel...

Страница 12: ...Digit shift key Pressing this key at setting mode makes the digit to be inputted on the temperature display to change Pressing this key for 5 seconds at temperature display mode causes the setting mod...

Страница 13: ...n or noise WARNING Install the unit on a sturdy floor If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit falling or tipping over Select...

Страница 14: ...floor Ensure the unit is horizontally Fig 1 3 Fixing the unit Two fixtures are attached to the rear of the frame Fix the frame to the wall with these fixtures and rope or chain Fig 2 Note Contact our...

Страница 15: ...page 14 The factory setting of chamber temperature is 5 o C Important When the power supply has been turn off wait 5 minutes or more after recovery of power supply connect the power supply plug to th...

Страница 16: ...e is displayed Turn on the power switch MPR S163 PE MPR S313 PE only 2 Press the set key SET The current setting is displayed and the first digit blinks 3 Set the temperature to 4 with the digit shift...

Страница 17: ...t key SET is not memorized DEFROSTING The following 2 types of defrosting methods is provided for the refrigerator Both of them are controlled automatically Cycle defrosting The chamber temperature is...

Страница 18: ...ift key and numerical value shift key When pressed the settable digit is shifted When pressed the figure of settable digit changes 4 Press the set key SET The current setting is displayed and the firs...

Страница 19: ...numerical value shift key for about 5 seconds F00 is displayed and the first digit blinks 3 Press the numerical value shift key and scroll the figure to 1 When pressed the figure of settable digit ch...

Страница 20: ...is displayed and the first digit blinks 3 Press the numerical value shift key and scroll the figure to 2 When pressed the figure of settable digit changes 4 Press the set key SET The current setting i...

Страница 21: ...rding to the condition of use Description of operation Key operated Indication after operation 1 The current chamber temperature is displayed 2 Press the numerical value shift key for about 5 seconds...

Страница 22: ...20 minutes from 30 minutes Following shows an example Change the setting as necessary Description Operation Key operated Indication after operation 1 The current chamber temperature is displayed 2 Pre...

Страница 23: ...ERMINAL OPTION A remote alarm terminal is mounted on the battery mounting box MPR 48B1 Optional component The alarm is outputted from this terminal Contact capacity is DC 30 V 2 A Contact output betwe...

Страница 24: ...1 installed Power failure alarm Power failure The power supply cord is disconnected The power switch is off MPR S163 PE MPR S313 PE only Power failure alarm MPR 48B1 installed Alarm indicator blinks I...

Страница 25: ...02 and 50 is displayed alternately The defrost sensor is disconnected Alarm indicator blinks E03 and chamber temp are displayed alternately The defrost sensor is short circuited Alarm indicator blinks...

Страница 26: ...iluted detergent always wipe it off with a wet cloth Then wipe off the cabinet or accessories with a dry cloth Important Never pour water onto or into the unit This may cause electric shock or failure...

Страница 27: ...sy The floor is not sturdy The installation site is not level The unit is tilted The cabinet contacts the surrounding wall When the refrigerator does not get cold enough The door is frequently opened...

Страница 28: ...method of disposal German Benutzerinformationen zur Entsorgung von elektrischen und elektronischen Ger ten private Haushalte Dieses Symbol auf Produkten und oder begleitenden Dokumenten bedeutet dass...

Страница 29: ...ter les autorit s locales ou votre revendeur afin de conna tre la proc dure d limination suivre Spanish Informaci n sobre la eliminaci n para los usuarios de equipos el ctricos y electr nicos usados p...

Страница 30: ...pe a informa es sobre o m todo de elimina o correcto Italian Informazioni per gli utenti sullo smaltimento di apparecchiature elettriche ed elettroniche obsolete per i nuclei familiari privati Questo...

Страница 31: ...act op met de lokale overheid of uw leverancier en vraag wat de juiste verwijderingsmethode is Swedish Information om kassering f r anv ndare av elektrisk elektronisk utrustning privata konsumenter Om...

Страница 32: ...our sales representative or agent for the attachment of a temperature recorder Temperature recorder Recorder fixing MTR 0621LH MPR S30 MTR G04A or MTR G04C MPR S7 INTERFACE BOARD OPTION Two kinds of...

Страница 33: ...Hermetic type Output 160 W Evaporator Fin and tube type Condenser Wire and tube Refrigerant R 407D Defrosting New cycle defrost and forced defrost Defrost heater 87 W 91 W USA only 101 W Other area Dr...

Страница 34: ...duct name Pharmaceutical refrigerator MPR S313 Model number MPR S313 PA MPR S313 PK MPR S313 PT MPR S313 PR MPR S313 PE Temperature control range Between 2 o C and 14 o C ambient temp 5 o C to 35 o C...

Страница 35: ...he unit Unit interior No contamination Decontaminated Contaminated Others 3 Instructions for safe repair maintenance disposal of the unit a The unit is safe to work on b There is some danger see below...

Страница 36: ...Printed in Japan LDCL035400 0 S0418 0 1 1 1 Sakada Oizumi machi Ora gun Gunma 370 0596 Japan PHC Corporation 2018...

Отзывы: