The reaction to a recognition of a ply change can take place either in one or two
steps.
One-step ply change
This function is used to activate the one-step ply change. A menu is opened for entering the
required parameters.
With the corresponding functions the values for
- sealing speed,
- sealing power and
- max. seam length
can be entered for the ply change section.
The sealing parameters are reset automatically at the end of ply change section
or at the latest after the maximum seam length has been sewn.
Two-step ply change
This function is used to activate the two-step ply change. A menu is opened for entering the
required parameters.
With the corresponding functions the values for
- sealing speed,
- sealing powers and
- max. seam lengths
can be entered for both ply change sections.