Preparation
24
Select the desired sequence number on the number block.
Confirm selection and quit selection menu, die production type "Programmed Sealing
with sequence program" is activated.
9
.03
Entering the sealing parameters
The direct input and alteration of sealing parameters is only possible in Manual or Dynamic
Sealing. In Programmed Sealing the direct input of the sealing parameters is not possible.
The alteration must be made in the appropriate sealing program, see Chapter
10.05 Crea-
ting/altering
a sealing program. Depending on the selected production type and the corres-
ponding pre-settings (power sealing/amplitude sealing) the following parameters can be alte-
red directly:
- Sealing power or sealing amplitude, see
Chapter
9.03.01
- Sealing speed, see
Chapter
9.03.02
- Roller pressure, see
Chapter
9.03.03
Switch on the machine, see Chapter
8.03, Switching the machine on/off
.
Call up program selection.
Call up manual sealing.
The screen displays described below only appear if manual sealing is selected.
If dynamic sealing is selected, the sealing speed input is different, see Chapter
9.03.02 Entering the sealing speed
.
●
●
●
●
●
In Programmed Sealing the direct input of the sealing parameters is not possib-
le. The alteration must be made in the appropriate sealing program, see Chapter
10.05 Creating/altering a sealing program
.
Power sealing (standard)
Amplitude sealing