55
11
.03
Further settings
The further settings are use for stipulating further machine settings, the choice of country
and access rights.
Switch on the machine.
Call up the input mode.
Call up the input menu for further settings.
●
●
●
Power sealing (standard)
Amplitude sealing
Description of the functions
Input mode
This function is used to change from the initial state to the input mode.
Sealing mode
This function is used to change to the sealing mode.
Feed unit backwards after stop
This function is used to enter the distance which the feed unit should move back after a
sealing stop.
Feed unit forwards at end
This function is used to enter the distance which the feed unit should continue moving after
the end of the sealing.
Automatic recognition of ply (only for power sealing)
This function is used to switch the automatic ply recognition function on or off, see Chapter
11.03.01 Automatic ply recognition
.
Flip-flop mode (pedal)
This function is used to switch the flip-flop mode for the pedal function on or off:
- Function switched on (symbol shown inverse)
The pedal function is carried out as soon as the pedal is brought into the appropriate
position and remains active after the pedal has been released.
- Function switched off
The pedal function is only carried out as long as the pedal is held in the appropriate
position.