Installation and commissioning
21
8
.02
Commissioning
Clean the machine thoroughly, also see Chapter
12 Maintenance
.
Check the machine, particularly its electrical wiring and pneumatic tube connections, for
any damage.
Have a qualified person check whether the motor can be driven with the existing power
voltage.
If there are any differences, the machine must definitely not be operated!
The machine must only be connected to a suitably earthed socket!
Connect the machine to the compressed air supply. When it is connected, the gauge
should indicate a pressure of approx.
6
bar. If necessary have this reading correctly set
(see Chapter
12.02 Checking/adjusting the air pressure
).
●
●
●
●
Operate the “basic position” function to confirm the switch-on operation.
Carry out a test run, see Chapter
10 Sealing
To switch off the machine, turn the main switch to the "o" position, see Chapter
7.02
Main switch
.
●
●
●
8
.03
Switching the machine on/off
To switch on the machine, turn the main switch to the "I" position, see Chapter
7.02 Main
switch.
●