Maintenance and Care
62
Fig. 12 - 04
12
.06
Cleaning the maintenance unit air fi lter
Switch off the machine!
Detach the compressed air
tube on the maintenance unit.
Empty
water tank 1
Water tank
1
empties itself automatical-
ly after the compressed air tube for the
maintenance unit has been removed.
Clean fi lter
2
:
Unscrew the water tank
1
.
Unscrew the fi lter
2
.
Clean fi lter
2
with compressed air or
isopropylalcohol (order no.
95
-
665
735
-
91
).
Screw in the fi lter
2
and screw on the
water tank
1
.
Fig. 12 - 05
2
1
1
2
12
.05
Checking/setting the air pressure
Check the air pressure on the manome-
ter
1
before every start-up.
T
he manometer
1
must show a pressure
of
6 bar.
Adjust this value if needed.
To do this, pull up the button
2
and turn
it so that the manometer
1
shows a
pressure of
6 bar.
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230