Adjustment
13
.06.05
Zigzag stitch movement
Requirement
When the needle, coming from the right point of needle entry, is in TDC (hole 2), the
needle bar must not move when the zigzag stitch width regulator is operated.
●
Loosen screws
1
slightly.
●
Bring needle bar to TDC (hole 2).
●
Move eccentric
2
until the distance from it to the right inner side of the housing is
approx.
5 mm
.
●
Turn eccentric
2
according to the requirement and tighten screws
1
.
5
1
2
3
4
Fig. 13 - 07
1
2
5 mm
13 - 8