Care and maintenance
12
.07
Compressed air unit
Fig. 12 - 12
12
.07.01
Checking and regulating air compression
●
Always check the air compression on the manometer
1
before operatint the machine.
The manometer
1
must indicate a pressure of
6
bar.
When required:
●
Pull up on knob
2
and turn so that the manometer
1
indicates a pressure of approx.
6
bar.
12
.07.02
Cleaning the air filter
The air filter must be cleaned whenever the working pressure of
6 bar
is no
longer achieved.
Turn off compressed air!
●
Unscrew drum
3
.
●
Remove filter element
4
.
●
Clean filer element
4
and drum
3
with benzine.
●
Blast filter element
4
from the inside out with compressed air.
●
When assembling, make sure that the seals are positioned properly.
●
Open compressed air.