© 2020 - perma-tec
GmbH & Co. KG
|
www.perma-tec.com
|
19
18
|
perma ECOSY
• Run tube lines - observe min. bending radius of 50 mm (2 in).
Secure lines.
• Shorten tubes with a tubing cutter. Make sure the cut is straight
and clean (At right angle to center line of tube. Slanted, rough
and chapped cuts will leak. For best results use tube cutter).
• Insert tube ends into lubricant outlets (6, Fig. 3-2) and make sure
they are tight and secure.
• Attach cover for pump area (4, Fig. 3-1). Finger tighten allen
screw.
5.3.2 Installing the ECOSY Control sensor
• Install control sensor. Ensure that connection cable is secure.
• Connect control sensor according to chapter 10.2.3.
• Check: turn perma ECOSY 5 on and hold a piece of metal to the
sensing end of the control sensor. If the control sensor was
attached correctly, an indication light will light up on the back
of the control sensor. The display will show an “S” for about 1
second.
• Adjust range (distance between control sensor end and piece
of metal 2 to 4 mm / 0.08 to 0.16 in). Hand tighten nut.
• If necessary, use the operating manual of the device or the
system that is going to be lubricated by perma ECOSY 5.
5.4
Connection to Power Supply
• Connect ECOSY 5 with power supply:
24 V DC
(see chapter 10.2) or
85 - 240 V AC
(see chapter 10.1)
Electrostatic charging of the operator may cause a RESET if the
operator touches any of the metal parts of the pump area. This
is of no importance.
NOTE