background image

 K-RAIN MANUFACTURING CORP.

1640 Australian Avenue
Riviera Beach, FL 33404 USA
PH: 1-561-844-1002 / 1-800-735-7246
FAX: 1-561-842-9493
www.krain.com

© K-RAIN Manufacturing Corp.  14005103REV13

 

  PRO

SPORT

 

 GEAR DRIVEN 

SPRINKLER SETTING INSTRUCTIONS 

NOTE:

  The 

Pro

Sport

 is factory preset with a 180° arc setting, and includes 

a pre-installed #10 nozzle.

CHANGING A NOZZLE

 

   1. REMOVING THE NOZZLE RETENTION SCREW 

Use the (

B

) end of the key to remove the nozzle retention screw (

L

) by turning 

counter-clockwise to remove and clockwise to re-install.

   2. PULL UP THE RISER 

Insert the (

A

) end of the key in the keyhole (

J

) on the top of the nozzle turret (

K

) and 

turn the key 1/4 turn to insure that the key does not slip out of the keyhole when you 
pull it up. Firmly pull up the entire spring-loaded riser to access the nozzle socket 
(

E

). Hold the riser assembly up with one hand.

   3. REMOVING THE NOZZLE 

Using a pair of needle-nose pliers, grasp the nozzle on the side of the outer ring and 
pull the nozzle out. 

   4. INSTALLING A NOZZLE

 

Press the desired nozzle into the nozzle socket. Make sure the nozzle
number is visible and the nozzle

 “prongs”

 are up. Then, re-install the

nozzle retention screw. 

NOTE:

 The nozzle retention screw is also a

break-up screw and used to adjust the distance of the spray.

SETTING THE ARC ADJUSTMENT

   1. FINDING THE LEFT START POSITION 

Place your fi ngers on the top center of the nozzle turret. Rotate the turret to the right 
until it stops and then back to the left until it stops. Notice the position of the nozzle 
arrow. This is the 

“Left Start”

 position. The sprinkler will begin spraying from this 

position and rotate clockwise until it reaches the right Adjustable Stop-Return Point.

   2. ORIENTING THE LEFT START POSITION 

Insert the (

A

) end of the key in the keyhole (

J

) on the top of the nozzle turret (

K

) and 

turn the key 1/4 turn to insure that the key does not slip out of the keyhole when 
you pull it up. Being careful not to allow the nozzle turret to turn, fi rmly pull up the 
entire spring-loaded riser. Hold the lower riser assembly up with one hand. Now turn 
only the lower riser clockwise or counter-clockwise until the nozzle arrow is pointing 
where you want the sprinkler to begin spraying.

   3. CHANGING THE ARC 

Insert the (

B

) end of the key into the Arc Set Adjustment slot (

M

). Turn clockwise to 

increase the arc or counter-clockwise to decrease the arc. 

NOTE:

 

The arc set arrow in 

the center of the nozzle turret rotates to show the current setting.

WHEN SET AT 360°, THE PRO

SPORT

  WILL ROTATE CONTINUOUSLY 

IN A CLOCKWISE DIRECTION.

SPRINKLER INSTALLATION

   1. INSTALL AND BURY 

Do not use pipe dope.Thread the sprinkler on the pipe. Bury the sprinkler fl ush to 
grade. 

NOTE:

 Gear driven sprinklers and pop-up sprays should not be installed on 

the same watering zone.

   2. INSPECTING THE FILTER 

Unscrew the top and lift the complete sprinkler assembly (

I

) out of the housing can. 

The fi lter is located on the bottom of the sprinkler assembly and can easily be pulled 
out, cleaned and re-installed.

   3. WINTERIZATION TIPS 

When using an air compressor to remove water from the system please  
note the  following:

a.

 Do not exceed 30 PSI.

b.

 Always introduce air into the system gradually to avoid air pressure surges.  

 

Sudden release of compressed air into the sprinkler can cause damage.

c.

 Each zone should run no longer than 1 minute on air. Sprinklers turn 10 to 12 

time faster on air than on water. Over spinning rotors on air can cause damage to 
the internal components.

    

PERFORMANCE

 

 

PRESSURE   

RADIUS  

FLOW

NOZZLES PSI 

FT. 

GPM

#5

 

 40 

45' 

5.1

WHITE

 50 

47'  5.9

 60 

47' 

6.5

 70 

49' 

7.1

 

  
#10  

 50 

53' 

10.6

GREEN

 

60 53' 

11.8

PRE-INSTALLED

 70 

53' 

12.6

 80 

55' 

13.5

 

#15  

50 57' 

13.0

GRAY

 60  59'  14.2

 70 

59' 

15.4

 80 

63' 

16.5

 

#20  

60 65' 

18.9

BROWN

 70 

67' 

20.5

 80 

69' 

21.9

 90 

71' 

23.2

 

#25  

  60 

67' 

22.8

BLUE

 70  71'  24.8

 80 

75' 

26.5

 90 

77' 

26.8

#30 

  60 

67' 

23.7

BLACK

 70 

69'  25.6

 80 

69' 

27.5

 90 

71' 

29.2

    

METRIC

 

 

PRESSURE    RADIUS  

FLOW

NOZZLES 

 KPA       BARS 

METERS 

L/M         M3/H

#5

 

 276  2.76  13.7 

19.3 

1.16

WHITE

 345 

3.45 

14.3 

22.3 

1.34

 414 

4.14 

14.3 

24.6 

1.48

 483 

4.83 

14.9 

26.9 

1.61

 

  
#10  

   345  3.45  16.2 

40.1 

2.41

GREEN

 

414 4.14 15.9  44.3  2.66

PRE-INSTALLED

 483 4.83 

16.2 47.7 2.86

 552 

5.52 

16.8 

51.1 

3.06

 

#15  

  345  3.45  17.4 

49.2 

2.95

GRAY

 414 

4.14 

18.0 

53.8 

3.23

 483 

4.83 

18.0 

58.3 

3.50

 552 

5.52 

19.2 

62.5 

3.75

 

#20 

 414  4.14  19.8 

71.5 

4.29

BROWN

 483 

4.83 

20.4 

77.6 

4.66

 552 

5.52 

21.0 

82.9 

4.97

 621 

6.21 

21.6 

87.8 

5.27

 

#25  

 414  4.14  20.4 

86.3 

5.18

BLUE

 483 

4.83 

21.6 

93.9 

 

5.63

 552 

5.52 

22.9 

100.3 

6.02

 621 

6.21 

23.5 

101.4 

6.08

#30 

 414  4.14  20.4 

89.7 

5.38

BLACK

 483 

4.83 

21.0 

96.9 

5.81

 552 

5.52 

21.0 

104.1 

6.25

 621 

6.21 

21.6 

110.5 

6.63

 PERFORMANCE  DATA

 M

 Arc Set Adjustment

 J

 Keyhole

K

 Nozzle Turret 

L

 Nozzle 

Retention 
Screw

G

 Nozzle

F

 

Can

I

 Sprinkler 

Assembly

H

 Key in Keyhole

K

  

Nozzle 
Turret

E

  Nozzle

 Socket

C

 Key in Keyhole

F

 

Can

Key

A

B

Left
Start

Adjustable 
stop-return point

 * Data represents test results in zero wind. Adjust for local conditions. Radius may be reduced with nozzle retention screw.