background image

MAN055 

– REV. 0   DATE: 11.01.2011      

 DRAFT BY:  U.T. 

PAG. 1 DI 9 

 

 
Acqua Brevetti 95 s.r.l. 

 

  

 

 

 

 

INSTALLATION AND OPERATING MANUAL 

  

 
 

 
 
 

 
 

 

 

SEMI-AUTOMATIC SELF-CLEANING FILTER WITH PRESSURE REDUCER  

 
 

 

 
 

 
 

 
 

 
 

 

BravoFIL Plus 

 

Semi-automatic  self-cleaning  filter  with 
pressure reducer. 
 
 
 
 
 
 
 

BravoFIL Plus 

 

Fittings 

Code 

¾”    

 

FT120 

1”     

 

FT122 

1”1/4 

 

FT124 

 
 
 
 
 
 
 
 
 
Read carefully this manual before use; keep 
this manual near the filter. 
 

Changes reserved!  

 

ENG 

Содержание BravoFIL Plus

Страница 1: ...OPERATING MANUAL SEMI AUTOMATIC SELF CLEANING FILTER WITH PRESSURE REDUCER BravoFIL Plus Semi automatic self cleaning filter with pressure reducer BravoFIL Plus Fittings Code FT120 1 FT122 1 1 4 FT12...

Страница 2: ...DI 9 Acqua Brevetti 95 s r l DIMENSIONS The dimensions are in mm Filter Code A B C D E F mm FT120 180 270 105 375 400 160 FT122 175 270 105 375 400 160 FT124 185 270 105 375 400 160 Document Revision...

Страница 3: ...ch as sand silt rust oxides The filter is equipped with a pressure reducer that lets you adjust the pressure downstream thereof in a range of values ranging from 1 to 6 bar The maximum diameter of par...

Страница 4: ...ments installed before the filter to eliminate any foreign body It is advisable to install shut off valves immediately up stream and down stream the unity It is advisable to install a by pass valve to...

Страница 5: ...e high mechanical and corrosion resistance Pressure reducer In the back plate connection is housed the pressure reducer which is pre calibrated at the factory with an outlet pressure of 3 bar This val...

Страница 6: ...t the turning of the green upper knob until the complete cleaning of the filtering cartridge is obtained Turn the filtering knob until the filtering position is reached with the discharge valve closed...

Страница 7: ...1 8 Insert a curved pincer inside the discharge valve and rotate it clockwise to close the valve completely 1 9 Screw the brass nut insert the green plastic cover and put in the fork up as the initial...

Страница 8: ...agraph 5 1 5 Placing the filter in phase Increase of the pressure downstream the pressure reducer in the presence of a boiler Water overheating increase of water volume Install an expansion tank The p...

Страница 9: ...ents for performances safety and testing Acqua Brevetti 95 S r l operates with a Quality System certified according to Standard UNI EN ISO 9001 2000 with certificate N 50 100 7368 drafted by T V Itali...

Отзывы: