perma ECOSY
8.3.1.1 Checking the Discharge Volume of an Outlet
8.3.2 Setting of Temperature Limit
perma ECOSY 5 is already shut down if the set temperature limit is
reached. This means that if -5 °C (23 °F) was set, the discharging
process will already be interrupted at -5 °C (23 °F) until the tem-
perature rises above this set value again.
ECOSY
System On
+20 °C
Menu
B1
Press “Menu”.
B2
Menu
Parameter
Configuration
OK << >> Esc
B2
Press “OK”.
B3
Parameter
Vol. outlet 1
Vol. outlet 2
OK << >> Esc
B3
Select “Temperature“ by pressing
the arrows “>>” once.
B13
Parameter
Temperature
Vol. outlet 1
OK << >> Esc
B13
Press “OK”.
B14
Parameter
Vol. outlet 3
0500 ml/1000h
Edit Esc
B11a
If you want to check the discharge
volume of a single outlet or of several
outlets, proceed as described under
8.3.1 until [B6] is shown.
B11a
Read the value.
Press “ESC” as many times as necessary
until you get to the main menu [B1].