8.4.1.3 Discharge Process in Operating Mode SENSOR
• In operating mode SENSOR, the ECOSY 5 reacts to the system status
of the machine to be lubricated. Only the machine‘s “ON” time is taken
into consideration. Downtimes are not factored in for the discharge.
Control sensor signals (impulses, 24 V) are sent by the machine.
• The discharge point is calculated based on the discharge volumes
selected / set, with only the machine‘s “ON” times being taken into
consideration.
• The objective is to convey the selected volume to the lube point in
equal amounts each time (programming basis is 1000 h – although
here this represents the number of hours worked by the machine).
ON
OFF
1
0
1 min
∆t ∆t+
20%
∆t ∆t+
20%
Control sensor signal (Controls / Sensor IN) of the machine to be lubricated
Discharge process in operating mode SENSOR
perma ECOSY system status and discharge cycle
t