perma PRO C
- 8 -
4.
Assembly and Mounting of the Lubrication System
4.1
Mounting the Drive Unit onto a Fixing Device for Wall-Mounting
♦ Attach the supplied mounting device to the drive unit using the two enclosed hex head bolts (M6 x 16) and
the two washers.
♦ Screw the mounting device with the drive unit onto a support of your system. The boring template of the three
mounting screws (141.5 x 45) can be seen below in fi gure 3 or on the template that is included. You have to
use at least three hexagon screws M6 x 25 (e.g. on metal ground).
♦ Before you connect the outlet of the drive unit to the lubricant tube, you have to make sure that the lubrication
points and the complete lubricant tube is pre-lubricated with the same lubricant that is contained in the PRO
LC unit. For that, perma-tec offers a 400 g lubrication cartridge for manually-operated grease presses with the
requested lubricant.
♦ Connect the lubricant tube (connection G3/8) to the outlet of the drive unit and install the tube correctly
between the outlet and the lubrication point. The lubricant tube must not be longer than fi ve meters.
Make sure that you assemble the connections and lubricant tubes correctly and tightly to avoid possible
leakage.
fi gure 3
2 hex head bolts
M6 x 16, maximum
torque 3 Nm
(supplied
for attaching the
perma PRO C to the
mounting device)
Hexagon screw
M6 x 25 (for wall
mounting on metal)
2 hexagon screws
M6 x 25 (for wall
mounting on metal)
143
45
141,5
Содержание Distributor PRO MP-6
Страница 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Страница 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...