perma PRO C
- 10 -
c)
♦ Place the PRO LC unit with its protection cover on the drive-unit. Make sure that the catch locks and that the
teeth of the PRO LC unit and the drive unit interlock (refer to fi gure 6).
♦ Turn the cover clockwise until the bayonet catch locks.
4.3
Connect the Connecting Cable to the Lubricator
♦ Connect the four strands of the connecting cable to the control system (e.g. a PLC) of your equipment and
pay attention to the pin assignment of the connector on the lubricator (refer to chart 2 and fi gure 7).
♦ Insulate the connected strands correctly.
♦ Insert the 4-pole connecting cable into the connector of the lubricator (refer to fi gure 6).
♦ Screw tight the connector socket of the connecting to the connector of the lubricator.
Pin no. of the connector
on the lubricator
Strand color of the
standard cable
Function
1
brown
Not assigned
2
white
Malfunction*
3
blue
Ground
4
black
Voltage (15 V to 30 V – DC)
chart 2
* Error signal is low-active! (negative logic)
fi gure 7
Pin assignment of the
connector on the lubricator
1
2
4
3
fi gure 6
Содержание Distributor PRO MP-6
Страница 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Страница 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...