Quick Reference Guide for the Lubrication System perma PRO C
On this page you will find some important information for quick and easy operation and setting of the perma PRO C
lubrication system. Before the first installation of the perma PRO C and whenever you need detailed instructions,
you should read the complete Operating Manual which contains information that must be observed. Make sure to
follow the instructions giving in the chapter “Safety Instructions”.
1
Assembly of perma PRO C / Exchange of PRO LC unit
(refer to chapter 4 and 7)
♦ Mount the drive unit on the mounting plate and secure it with the three pre-drilled holes (see attached
template).
♦ Place the PRO LC unit inside the cover and remove the plug of the PRO LC unit.
♦ Push the PRO LC unit into the cover until lubricant comes out of the opening.
♦ Place the PRO LC unit with its cover on the drive-unit. Make sure that the catch locks and that the
teeth of PRO LC unit and drive unit interlock.
♦ Turn the cover clockwise until the bayonet catch locks.
♦ Connect the perma PRO C to your control system using the connecting cable.
2
Determine the Discharge Period
(refer to chapter 6.7)
♦ Refer to the manufacturer’s guidelines about the lubrication point that you want to lubricate in order to
determine the required lubricant amount in cm
3
per one hundred operating hours.
♦ Refer to chart (chapter 6.7, chart 5) and find your required lubrication volume. Based on that, the chart will
show you the required PRO LC unit size, the setting of the discharge period, and the setting mode.
♦ You may also refer to our perma SELECT program which can be downloaded from our web page free of
charge. It helps you in selecting the correct settings.
3
Setting of LC unit Size, Discharge Period, Outlets and PIN
(refer to chapter 6.8
)
♦ Hold down the MODE/SAVE button until the set time is displayed.
♦ Hold down the MODE/SAVE button again until you reach the current PIN (PIN cannot be changed here /
PIN setting at delivery is “ ”).
♦ Hold down the MODE/SAVE button again until you reach the other setting menus:
LC unit, discharge period, outlets (only with attached MP-6), and PIN change.
Change settings with a short push of MODE/SAVE or SELECT.
4
Impulse Mode via the Connected Control System
(refer to chapter Kap. 6.10)
♦ To start the impulse mode, set the setting mode “Days” in the configuration menu of the lubricator to “ ”.
♦ Trigger a discharge with a discharge volume of 0.5 cm
3
by switching on the supply voltage for the
perma PRO C for a minimum operating period of 14 minutes.
♦ The minimum shutdown period between two discharges is 20 seconds.
5
Save Settings
(refer to chapter 6.8)
♦ Keep the MODE/SAVE button pressed until display shows “ ”.
6
Starting perma PRO C
(refer to chapter 4.3 and Kap. 6.5)
♦ Switch on the supply voltage (DC 15 V to 30 V) for the lubricator via your control system. The remaining
volume is displayed and the green LED is blinking.
7
Stopping perma PRO C
(refer to chapter 6.6
)
♦ Switch off the supply voltage for the lubricator. The display of the lubricator shows “ ”.
Содержание Distributor PRO MP-6
Страница 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Страница 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Страница 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...